THERMOSALD UPSCR_N_V5 - OPERATOR MANUAL - Rev. 2006 / 07
Page N. 9
- Tot: 18
10 – Display = “ _ B A L ” / “Temperature” – START UP COLD BALANCING BY TRIMMER
(TO TOUCH AND ROTATE ONLY IN THE COURSE OF FIRST START UP)
10 – Press the key RESET (ON DISPLAY DISAPPEAR THE “ B “ OF “ B 0 2 0 “ AFTER SOME SECONDS)
(From software release V4.9 it is possible press also the keys DOWN + UP)
11 – Keep the key RESET pressed for 3 seconds to start the AUTOMATIC BURN-IN CYCLE
THE MACHINE IS READY TO WORK.
NOTE: After the BURN IN cycle, sealing bands modify a little its electric characteristic, but are stable. If pay
attention can observe that temperature of sealing bands is some degree lower then before burn_in cycle. Do not
modify temperature by rotating balancing trimmer (used only in the course of first start up, after a master reset) or
pressing the up/down keys to do an automating balancing (used only after a change of the sealing band)
NOTE: It’s possible to do the machine more hot increasing HOT FACTOR value, parameter 5; From software
release V4.9 it’s possible to change it pressing the keys DOWN+T/I for 3 seconds, parameter nr. 5 appears, change
the value by key DOWN or UP, wait 6 seconds to return to main menu.
(As previous software release, it’s possible to change this parameter entering in the SETTING DATA or HOT
CALIBRATION DATA, pressing key UP+RESET 6 seconds, see ANNEX C)
NOT BALANCED SYSTEM
- On the display appears alternatively “ B A L ” and “temperature value not balanced ” to
remember that green/red led balancing need to do (Note: a red bar down before “ B A L “
means unbalance towards down; a red bar up before “ B A L “ means unbalance towards up;
the wording “ T - - - “ means temperature overflow toward down).
- rotate balancing trimmer clockwise to light green led, rotate anticlockwise to light red led;
update of green/red led is 1 time in a second, so to calibrate fine it is necessary to rotate
balancing trimmer and wait up to aone second to wait update condition.
- When green and red leds are light both, the thermoregulator is balanced; we advise to read
temperature value on the display and rotate trimmer untill having 20 degree, if 20 degree is
the temperature of the gripper jaws: in any case the termoregulator will do next an automatic
perfect balancing.
BALANCED SYSTEM
- On the display appears fixed “ B 0 2 0 “, if 20 degree is temperature of the gripper jaws;
- When green and red leds are light both, the thermoregulator is balanced; we advise to read
temperature value on the display and rotate trimmer untill having 20 degree, if 20 degree is
the temperature of the gripper jaws: in any case the termoregulator will do next an automatic
perfect balancing.
On the display appears “ H100” , to inform that the first heating at 100
degree is in progress; next the writing H160, H100, H160, H100,
H160, H100 will appear to inform that cycles of heating and colding at
160 and 100 degrees are in progress. At the end the termoregulator will
be ready to work.
Burn in cycle can be stopped before end pressing key reset.