• The two digits representing the minutes will be turn on. Press button (3) or (4) to enter the minutes of the first cycle start time. To 
confirm the selection press the button (1)
• The first start up time for Monday has now been set. 
Then the inscription OFF1 will appear in the display and the two digits representing the hours will turn on. Press button (3) or (4) to 
enter the time for the first shut off. To confirm the selection press the button (1)
• The two digits representing the minutes will be turn on. Press button (3) or (4) to enter the minutes for the first shut off. To confirm 
the selection press the button (1)
• At this point the first on-off cycle for Monday has been entered. 
Later,  it  is  possible  to  set  the  Monday’s  second  and  third  on-off  cycle  (shown  with  the  display  of  On2  and  OFF2)  and  the  third 
Monday’s  on-off  cycle  (shown  with  the  display  On3  and  OFF3).  Inside  the  programming  menu,  if  for  example  the  Wednesday’s 
programming is to be changed, go to the third green led by pressing key (2): then edit the on-off program times for Wednesday and 
confirm  by  pressing  button  (6).  If  the  second  on-off  cycle  is  not  required  simply  set  the  On2  time  as  00:00  and  the  Off2  time  as 
00:00 . 
•  To  end  the  programming  process  press  button  (6)  several  times  or  exit  the  programming  menu.  To  enable  or  disable  the 
programming  process  press  button  (5);  the  programming  is  enabled  when  on  cr  appears  on  the  display  and  the  steady  LED 
appears in the bottom right corner of the display; programming is disabled when the of cr appears momentarily on the screen and 
the LED in the bottom right corner of the display goes off. This function activates or deactivates the settings programmed for the 
week. When the programming is active the operating conditions at ignition (combustion level – ventilation speed) are the same as 
those set before the last shut down, but only if the shut down occurred through programming, that is, not manually. 
Caution: in case the off-cycle (if carried out while the heater cycle is being controlled by the programming) is activated manually, at 
the  next  start  up  controlled  by  the  programming  the  heater  will  be  set  at  the  1st  combustion  power  level  and  the  1st  ventilation 
speed. 
• In order to display the present time and programmings, key (6) must be repeatedly pressed until the current time is displayed. 
Press button (3) or (4) to view all the programming values: to exit press button (6) twice. CAUTION: to change the programming day 
press button (3) or (4) 6 times in succession. 
• If you wish to start the heater after a programmed shut down, disable the CHRONO and press button (1) several times. 
 

In  the  event  of  a  programmed  cycle  on  always  ensure  that  the  brazier  is  clean  and  seated  correctly  in  its  lodging: 
failure to clean the brazier can reduce the life of the spark plug and be a hazard for the user. 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
When the programming is enabled (temporary inscription on cr on the display and, at the same time, a fixed LED is 
present on the right side at the bottom of the display) any additional chronothermostat (see para. 7.2) is deactivated. 

 

5.4   OPERATING LEVEL SETTING 

The heater must be fed with the rear switch in position "1".  
Display (7) may show the inscriptions On, OFF or Star
 
The appliance has an inbuilt program optimised to favour combustion efficiency; this program appears on the display with P 1
However,  if  you  use  poor  quality  pellets  which  have  different  combustion  residues  compared  to  those  that  comply  with  current 
regulations, it is possible to select other pre-programmed combustion levels. 
P 2: is an operating program that increases the speed of the smoke suction unit. This program increases the air flow to the burner 
to improve combustion of more tightly compacted wood pellets: When P 2 is selected, the combustion efficiency could drop. 
P 0: this program is useful when using pellets that are too long and/or flue outlets with very high vacuum, over  2 mm water column. 
 
 
To modify the program, proceed as follows: 
• press three times the key (6) until the inscription LIV flashes on the display and, then, the corresponding level set on the heater 
will show ( P1 or P2 or P0

POINT STEADY PRESENCE 

POINT ABSENCE 

EXAMPLE OF THE DISPLAY WITH THE PROGRAMMING ACTIVATED 

EXAMPLE OF THE DISPLAY WITH THE PROGRAMMING DEACTIVATED 

Содержание CIAO

Страница 1: ......

Страница 2: ...PANEL 0 5 1 1 DESCRIPTION OF THE CONTROL PANEL 0 5 1 2 BACK PANEL 0 5 2 DAY AND TIME SETTING 0 5 3 ON OFF PROGRAMMING 0 5 4 OPERATING LEVEL SETTING 0 6 USE OF THE APPLIANCE 0 6 1 SWITCHING ON THE HEATER 0 6 2 COMBUSTION AND VENTILATION ADJUSTMENTS 0 6 3 INFRARED REMOTE CONTROL 0 7 ROOM TEMPERATURE THERMOSTAT CHRONOTHERMOSTAT not supplied 0 7 1 OPERATING WITH THE ROOM TEMPERATURE THERMOSTAT not sup...

Страница 3: ...LATION 0 12 3 TROUBLESHOOTING CAUSE SOLUTION 0 13 SPARE PARTS MODEL CIAO 0 13 1 MAIN COMPONENTS AND THEIR POSITION 1 5 0 13 2 MAIN COMPONENTS AND THEIR POSITION 2 5 0 13 3 MAIN COMPONENTS AND THEIR POSITION 3 5 0 13 4 MAIN COMPONENTS AND THEIR POSITION 4 5 0 13 5 MAIN COMPONENTS AND THEIR POSITION 5 5 0 14 REPAINTING OF THE CASING MODEL CIAO 0 14 1 FOREWORD 0 14 2 DISMANTLING THE SIDE PANELS AND F...

Страница 4: ...Pg 4 EC DECLARATION OF CONFORMITY MODEL CIAO ...

Страница 5: ...Pg 5 EC DECLARATION OF CONFORMITY MODEL 2000 ...

Страница 6: ...over with it Thermorossi S p A retains copyright on theses service instructions These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation 1 2 SAFETY GUIDELINES PERSONAL INJURY This safety symbol identifies important messages throughout the manual Read the information marked by this symbol carefully as non observance of th...

Страница 7: ... wet hands Never vacuum hot ash this could damage the vacuum device All the cleaning operations described in this manual must be carried out when the appliance is cold Caution Warning for Swiss users Refer to the local cantonal regulations imposed by the Fire Department Mandatory signalling and safety distances and the Note concerning installation of heaters issued by the Association of Cantonal F...

Страница 8: ...eliability and optimal performance 3 2 THE PELLET The heater is fuelled by pellets that is cylinders of compressed sawdust this allows you to fully enjoy the heat of the flame without having to manually stoke the combustion The pellets have a 6 mm diameter and a maximum length of 15 mm They have a maximum moisture content of 8 thermal value 4000 4500 Kcal Kg and density of approx 620 630 Kg m It i...

Страница 9: ...r verifying directly or indirectly that the installation has been carried out to perfection in accordance with relevant regulations in force Do not install the appliance in unsuitable rooms such as bedrooms bathrooms garages and or lock ups It is forbidden to place the appliance in environments with an explosive atmosphere ATTENTION the stove is not simply a household appliance if the instructions...

Страница 10: ...five possible power levels displayed by the five leds progressively coming on in sequence 10 The shutdown cycle appears on the display when all the five power leds 10 are off The button 2 controls the ventilation of the heater It is activated when the heater reaches a temperature equal to or greater than 42 C Ventilation can be regulated up to six speed levels 9 When the heater is on the ventilati...

Страница 11: ...fixed inscription days will appear In order to adjust the day repeatedly press key 4 or 3 until the led turns on in area 9 which corresponds to the present day Monday is indicated by the 1st led on Tuesday is indicated by the 2nd led on Saturday is indicated by 6th led on while Sunday corresponds to all six leds being on Then confirm the day by pressing the key 1 The two digits representing the ho...

Страница 12: ...e programming is activated manually at the next start up controlled by the programming the heater will be set at the 1st combustion power level and the 1st ventilation speed In order to display the present time and programmings key 6 must be repeatedly pressed until the current time is displayed Press button 3 or 4 to view all the programming values to exit press button 6 twice CAUTION to change t...

Страница 13: ... appliance is restarted after it has run out of pellets and shut down the appliance may fail to light This is due to the fact that the screw feeder is completely empty In this case it is necessary to start the lighting procedure all over again Check that the brazier is in the correct position The lighting process Star on the display lasts 20 minutes During this time the heater ignores all the vent...

Страница 14: ... well as the room temperature with the chronothermostat you can also set the time and date for the on off cycles for the various days of the week It is therefore possible to program a momentary shutting down of the heater according to the room temperature CAUTION If you select an inappropriate value for the room temperature the heater will be subjected to continual on off cycles with consequent in...

Страница 15: ... carefully remove all ash residues from the area Figures 5a 5b and 5c EVERY MONTH remove the right side panel of the heater Figure 6a and clean the room fan grill Figure 6b EVERY MONTH when the fuel tank is empty vacuum the pellet dust deposited on the bottom of the tank AT THE END OF THE WINTER SEASON OR WHENEVER NECESSARY thoroughly clean the firebox and behind the combustion chamber of the heat...

Страница 16: ...Pg 16 Figure 4 ...

Страница 17: ... the regulations in force 8 4 REPLACING THE BATTERY OF THE CONTROL PANEL FOR MODEL CIAO Inside the control panel there is a buffer battery type CR2032 When the time and programming are not being memorised then the battery needs replacing Undo the two screws A which can be reached by opening the pellet tank cover Slide the control panel B out from the back and undo screws C to remove the protection...

Страница 18: ... on the outer walls or through single or multiple ventilation ducting paragraph 9 2 1 The ventilating air must come from outside and if possible away from sources of pollution The openings in the walls must comply with the following conditions have an unobstructed section of at least 6cm for each Kw of installed thermal power with a minimum limit of 100cm be made in such a way that the vent openin...

Страница 19: ...ve requirements of the Ministerial Decree DM 37 08 ex Italian Law 46 90 and to the applicable specific installation regulations according to the type of fuel Fireplaces heaters and barbecues must not be installed in locations where gas appliances type A and type B are present and operating for the classification see UNI 10642 and UNI 719 The connection between the appliance and the flue outlet mus...

Страница 20: ...ERA DI ACCIAIO A TENUTA STAGNA WATERTIGHT STEEL SHEET Legenda figura in basso a destra Key bottom right figure 2 metri MAX 2 metres MAX Pendenza non inferiore al 5 Minimum slope 5 2 3 metri MAX 2 3 metres MAX ALTEZZA SUPERIORE A 4 metri HEIGHT MORE THAN 4 m ISPEZIONE COMIGNOLO E CANNA FUMARIA SECONDO NORMA UNI 10683 INTERNO ESTERNO Tutte le tubazioni devono essere termicamente isolate Tutte le tub...

Страница 21: ... the discharge path The appliance functions with the combustion chamber in a vacuum while the discharge of smoke to the flue outlet has a slight pressure consequently it is imperative to ensure that the discharge system is hermetically sealed The smoke discharge tube must be made from suitable materials such as for example porcelain coated steel tubes and the various fittings sealed with red silic...

Страница 22: ...P R E S S O S T A T O T E R M O S T A T O95 C T E R M O S T A T O42 C S C H E D AC O M A N D O LEGENDA KEY CRONOTERMOSTATO AGGIUNTIVO TERMOSTATO AMB AGGIUNTIVO PRESSOSTATO TERMOSTATO 95 TERMOSTATO 45 SCHEDA COMANDO RESISTENZA MOTORE CARICO PELLETS TERMOSTATO RIARMO MANUALE ASPIRATORE FUMI VENTILATORE AMBIENTE CHRONOTHERMOSTAT ADDITIONAL ROOM THERMOSTAT ADDITIONAL PRESSURE SWITCH Thermostat 95 Ther...

Страница 23: ...plastic cover of the thermostat located at the back of the heater and pressing the button the heater temperature must be below 117 C GLOW PLUG It is activated in the switching on phase It heats the air flowing into the brazier up to 800 C whic h causes the pellets in the brazier to ignite and begin the combustion process 12 2 GUIDELINES FOR CORRECT INSTALLATION Read this instruction booklet The ap...

Страница 24: ... OF SMOKE DISPLAY SHOWS THE INSCRIPTION AL OP EMPTY THE BURNER AND CLEAN IT UP CHECK THE SMOKE EXHAUST AS IT COULD BE CLOGGED OUTLET TERMINAL CLOGGED BECAUSE A GRILL OR TERMINAL HAS BEEN INSERTED WHICH PREVENTS THE FREE PASSAGE OF SMOKE DISPLAY SHOWS THE INSCRIPTION AL OP EMPTY THE BURNER AND CLEAN IT UP CHECK THE SMOKE OUTLET AND REMOVE THE GRILL OR TERMINAL GUST OF WIND WHICH HAS MADE THE APPLIA...

Страница 25: ...L BURNER IS DIRTY EMPTY THE BURNER AND CLEAN IT AS INDICATED IN THIS MANUAL PELLETS WITH DEPOSIT ABOVE PERMISSBILE LIMITS EMPTY THE BURNER AND CLEAN IT AS INDICATED IN THIS MANUAL SET THE OPERATING PROGRAM P2 THE APPLIANCE ACCUMULATES PELLETS IN THE BRAZIER DURING THE STANDARD OPERATION THE BURNER IS NOT PROPERLY PLACED ON ITS SEAT EMPTY THE BURNER AND CLEAN IT AS INDICATED IN THIS MANUAL REPOSITI...

Страница 26: ...Pg 26 THE APPLIANCE OPERATES WITH FREQUENT ON OFF CYCLES THE APPLIANCE NEEDS TO OPERATE AT A HIGHER POWER LEVEL ...

Страница 27: ...STAT IS SET TOO LOW SET A HIGHER TEMPERATURE THE APPLIANCE IS SWITCHED OFF BUT THERE ARE STILL UNBURNT PELLETS IN THE BRAZIER PELLET TANK IS EMPTY DISPLAY SHOWS THE INSCRIPTION AL PE EMPTY THE BURNER AND CLEAN IT UP FILL UP THE TANK WITH PELLETS THE APPLIANCE SHUTS OFF 25 MINUTES AFTER THE START UP CYCLE THE 42 C THERMOSTAT IS BROKEN OR FAULTY REPLACE THE 42 C THERMOSTAT THE SLIDING COVER MODEL 20...

Страница 28: ...Pg 28 IN THE MEMORY IF THE RECOMMENDED REMEDIES DO NOT SOLVE THE PROBLEM CONTACT A TECHNICAL ASSISTANCE SERVICE ...

Страница 29: ...Pg 29 13 SPARE PARTS MODEL CIAO 13 1 MAIN COMPONENTS AND THEIR POSITION 1 5 70014557 MANIGLIA APRI PORTA DATI DI TARGA 70014765 70014766 LEGENDA KEY MANIGLIA PORTA DOOR HANDLE DATI DI TARGA DATA PLATE ...

Страница 30: ...773 SCHEDA COMANDO 60013772 TARGHETTA PANNELLO COMANDI 70015626 SINISTRO COMPLETO 70015625 DESTRO COMPLETO LEGENDA KEY SUPPORTO PANNELLO COMANDI CONTROL PANEL SUPPORT SCATOLA CHIUSURA VANO PROTECTION COVER SCHEDA COMANDO CONTROL BOARD TARGHETTA PANNELLO COMANDI CONTROL PANEL DATA PLATE CORNICE FRAME VETRO GLASS DESTRO COMPLETO RH COMPLETE SINISTRO COMPLETO LH COMPLETE STAFFA BRACKET ...

Страница 31: ...650 NERODESTRO 70015652 GRIGIODESTRO 70015654 CELESTEDESTRO 70015656 VERDEDESTRO 70015658 ROSSODESTRO 70015651 NEROSINISTRO 70015653 GRIGIOSINISTRO 70015655 CELESTESINISTRO 70015657 VERDESINISTRO 70015659 ROSSOSINISTRO 70015649 BIANCOSINISTRO KEY KEY WHITE RH LH WHITE RH LH BLACK RH LH BLACK RH LH GREY RH LH GREY RH LH BLUE RH LH BLUE RH LH GREEN RH LH GREEN RH LH RED RH LH RED RH LH ...

Страница 32: ...C THERM 42 C CASSETTO COMPLETO COMPLETE DRAWER 60013827 60013760 60013761 70014758 70014766 70014765 70014743 70014769 70011242 70014770 CASSETTO COMPLETO 70014773 70014775 70013637 70014763 60013761 60013760 60013827 60011656 60011750 70015088 70015403 60010343 Term 42 C ...

Страница 33: ...0005964 VENTILATORE 60010188 60010114 60010188 60010149 60011428 60011630 CONDENSATORE 70012316 60010335 GUARNIZIONE 60010336 GUARNIZIONE 70015222 PORTACOMPLETA 60011454 FINECORSA 60010344 Term 95 C 60013559 70012315 Aspiratorefumicompleto LEGENDA FIGURA FIGURE KEY GUARNIZIONE GASKET VETRO GLASS MANIGLIA COMPLETA COMPLETE HANDLE FINE CORSA STOP PORTA COMPLETA COMPLETE DOOR CONDENSATORE CONDENSER T...

Страница 34: ...e floor and the casing 14 2 DISMANTLING THE SIDE PANELS AND FRONT GLASS Remove the side panels A Remove the front glass panels B by undoing the screws at the rear C 14 3 DISMANTLING THE STOVE BODY AND CASING Lay the heater down as illustrated in the figure Undo the six screws D Carefully pull the body away from the casing at least two people are required for this operation This operation must be c...

Страница 35: ...1 MAIN COMPONENTS AND THEIR POSITION 1 3 70015784 BEIGE 70015504 BEIGE 70016103 70016102 70015824 NERO 70015825 BIANCO 70015826 ROSSO 70015827 NERO 70015828 BIANCO 70015829 ROSSO LEGENDA KEY BEIGE BEIGE NERO BLACK BIANCO WHITE ROSSO RED ...

Страница 36: ...0013637 70014743 70016101 70014770 CASSETTO COMPLETO 70014775 70014773 60005254 70016111 70016110 60012773 Scheda comando 60013772 Targhetta pannello comandi LEGENDA FIGURA FIGURE KEY CASSETTO COMPLETO COMPLETE DRAWER SCHEDA COMANDO CONTROL BOARD TARGHETTA PANNELLO COMANDO CONTROL PANEL DATA PLATE ...

Страница 37: ... 60010335 GUARNIZIONE 60010336 GUARNIZIONE 70015222 PORTACOMPLETA 60011454 FINECORSA 70015392 BEIGE 70015830 NERO 70015831 BIANCO 70015832 ROSSO 60013843 SETCORSIECOMPLETO 70015780 70012315 Aspiratorefumicompleto LEGENDA FIGURA GUARNIZIONE VETRO MANIGLIA COMPLETA FINE CORSA PORTA COMPLETA Aspiratore fumi completo CONDENSATORE SET CORSIE COMPLETO BEIGE NERO BIANCO ROSSO TERM 95 C Ventilatore comple...

Страница 38: ...Pg 38 NOTES ...

Страница 39: ...Pg 39 NOTES ...

Страница 40: ...Pg 40 NOTES ...

Отзывы: