background image

 

 

1

 

GAS STOCK POT STOVE 

 

 

 

 

 

 

 

Kasap Tip Dik Buzdolapları 

 

 

 

 

 

 

CONTENTS 

GENERAL INFORMATION 

Page  2

 

A1 

PRODUCT DESCRIPTION 

Page 

A2 

TECHNICAL INFORMATION 

Page 

A3 

TRANSPORTATION 

Page 

A4 

UNPACKING 

Page 

INSTALLATION 

 

 

 

 

Page  4 

SAFETY INSTRUCTIONS 

 

 

 

Page  5

 

OPERATION   

 

 

 

 

Page  6

 

CLEANING & MAINTENANCE  

 

 

Page  7 

TROUBLESHOOTING   

 

 

 

Page  8 

INJECTOR CHANGE AND GAS SETTING 

 

Page  9 

GAS CONNECTION IMAGES   

 

 

Page  10

 

SPARE PART LIST- EXPLODING DRAWING   

Page  13

 

 

 

Summary of Contents for EMP.YRG.50

Page 1: ...A2 TECHNICAL INFORMATION Page 3 A3 TRANSPORTATION Page 3 A4 UNPACKING Page 4 B INSTALLATION Page 4 C SAFETY INSTRUCTIONS Page 5 D OPERATION Page 6 E CLEANING MAINTENANCE Page 7 F TROUBLESHOOTING Page 8 G INJECTOR CHANGE AND GAS SETTING Page 9 H GAS CONNECTION IMAGES Page 10 I SPARE PART LIST EXPLODING DRAWING Page 13 ...

Page 2: ... disobeying instructions and regulations wrong connections Unauthorized intervention to appliance invalidates the warranty 1 This instruction manual should be kept in a safe place for future reference 2 Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel 3 This appliance has to be used by trained person 4 Please turn off the...

Page 3: ...x860x670 EMP YRG 70 700x800x500 80 720X950X585 EMP YRG 80 700x800x500 80 720X950X585 A2 TECHNICAL INFORMATION Product Code Model Power KW Gas Consumption NG Gas Consumption LPG EMP YRG 50 Gas Stock Pot Stove With Valve 9 3 0 7 kg h EMP YRG 60 Gas Stock Pot Stove Without Valve 12 3 2 m h EMP YRG 70 4 Ring Stock Pot Stove Without 32 2 4 kg h EMP YRG 80 4 Ring Stock Pot Stove With Valve 32 3 3 m h A3...

Page 4: ...appliance is must have enough ventilation and vent hole The appliance must be connected correctly according to local and national gas standards of your country The appliance gas entrances are indicated with G label on the body Connection to gas fitment must be done with suitable diameter metal flex pipe and spheric valve The spheric valve must be immobilized to a place that is far away from heat a...

Page 5: ...r more than appliance s capacity Do not attempt to use the appliance without suitable protective equipments Because of any reason if there is a fire or flame flare where the appliance is used turn off all gas valves and electric contactor switch quickly and use fire extinguisher Never use water to extinguish the fire If there is gas leakage where the appliance is do not fire absolutely and do not ...

Page 6: ...AME POSİTİON EMP YRG 50 EMP YRG 60 EMP YRG 70 EMP YRG 80 Operating Press gas button in order to operole the appliace and ignile during pushing After ignition keep pressing on button for a few seconds in order to heat enasgh the thermocosple Select the position aflerwords full flame holf flame To begin the cooking process later ...

Page 7: ...nce with pressure water Do not clean the appliance with a materials that may hurt chrome material Wash the grills with hot water and then dry after every use PERIODIC CLEANING AND MAINTENANCE Maintenance should be done by qualified person These parts Gas storage thermocouples taps burner lighter and spark plug cable are not maintained so they need to be changed when they have error Check the gas c...

Page 8: ...tting or not THE APPLIANCE STOPPED 1 At EMP YRG 60 YRG 80 the gas flow is stopped automatically when the flame is off due to having gas tap that has safety valve In this situation the appliance is not operated 2 When there is gas leakage if there is solenoid gas stopper alarm gas flow is stopped and the appliance is not operated Ventilate the area through the agency of vent hole If cooking at gas ...

Page 9: ...0 mbar 1 20 1 80 0 22 50 mbar 0 20 G31 37 mbar 0 22 50 mbar 0 20 EMP YRG 50 EMP YRG 60 Burner Injectors Change 1 Remove cost grill and burner top cover Image 1 2 Chage c injector with consideration of valve on table above for this purpose first temove b inion from d gas inlet pipe Image 2 EMP YRG 60 EMP YRG 80 Safety valve In case of involuntary flame out ı safety valve will cut gas leakoge if h t...

Page 10: ...10 GAS STOCK POT STOVE Kasap Tip Dik Buzdolapları H GAS CONNECTION IMAGES Image 1 Image 2 EMP YRG 50 EMP YRG 60 ...

Page 11: ...NER INJEKTOR CHANGE 1 Remove cost gril land burner top cover you can odjust gas by turning g ıf you turn ıt on left hand side it will increose and you can reduce by turning on right hand side Image 1 2 CHANGE B ınjector by considering the valve on table above fort his purpose loosen F screws complety ond then c nuts Pull back injector steel d Remove volves e and injector Image 2 EMP YRG 60 EMP YRG...

Page 12: ...12 GAS STOCK POT STOVE Kasap Tip Dik Buzdolapları H GAS CONNECTION IMAGES Image 1 Image 2 ...

Page 13: ...PRODUCT NAME P CODE 1 BASE FRAME Y EMP YRG 50 1001 2 FEET Y EMP YRG 50 1002 3 CASTING GRILL Y EMP YRG 50 1003 4 BURNER Y EMP YRG 50 1004 5 BUTTON Y EMP YRG 50 1005 6 GAS TAP Y EMP YRG 50 1006 7 INJECTOR GROUP Y EMP YRG 50 1007 8 BURNER BARCKET Y EMP YRG 50 1008 9 BUTTON BUFFER Y EMP YRG 50 1009 10 GAS TANK Y EMP YRG 50 1010 ...

Page 14: ...ODE 1 BASE FRAME Y EMP YRG 60 1001 2 FEET Y EMP YRG 60 1002 3 CASTING GRILL Y EMP YRG 60 1003 4 BURNER Y EMP YRG 60 1004 5 BUTTON Y EMP YRG 60 1005 6 GAS TAP Y EMP YRG 60 1006 7 INJECTOR GROUP Y EMP YRG 60 1007 8 BURNER BRACKET Y EMP YRG 60 1008 9 BUTTON BUFFER Y EMP YRG 60 1009 10 GAS TANK Y EMP YRG 60 1010 11 THERMO PART Y EMP YRG 60 1011 ...

Page 15: ...CODE 1 BASE FRAME Y EMP YRG 70 1001 2 FEET Y EMP YRG 70 1002 3 CASTING GRILL Y EMP YRG 70 1003 4 BURNER Y EMP YRG 70 1004 5 BUTTON Y EMP YRG 70 1005 6 GAS TAP Y EMP YRG 70 1006 7 INJECTOR GROUP Y EMP YRG 70 1007 8 BURNER BRACKET Y EMP YRG 70 1008 9 BUTTON BUFFER Y EMP YRG 70 1009 10 GAS TANK Y EMP YRG 70 1010 11 T BRACKET Y EMP YRG 70 1011 ...

Page 16: ... Y EMP YRG 80 1001 2 FEET Y EMP YRG 80 1002 3 CASTING GRILL Y EMP YRG 80 1003 4 BURNER Y EMP YRG 80 1004 5 BUTTON Y EMP YRG 80 1005 6 GAS TAP Y EMP YRG 80 1006 7 INJECTOR GROUP Y EMP YRG 80 1007 8 BURNER BRACKET Y EMP YRG 80 1008 9 BUTTON BUFFER Y EMP YRG 80 1009 10 GAS TANK Y EMP YRG 80 1010 11 THERMO PART Y EMP YRG 80 1011 12 T BRACKET Y EMP YRG 80 1012 ...

Reviews: