thermopatch.com
36
10. Faults
If a problem should occur, please consult the list below; if the problem you are facing cannot
be solved by yourselves contact your supplier.
Fault
Possible cause
Solutions
Heating plate does not
heat up.
1. ON/OFF switch is not set to ON
2. Machine is not connected to the
electricity grid
3. Electronics not connected to
the
machine
4. Temperature sensor defective
5. Electronics wrongly set
6. Electronics defective
7. Heating element defective
Check
Check
Check
Check
Check
Check
Check and replace when
necessary
Heating plate is too hot
or too cold.
1. Check the temperature settings Correct
Machine opens too soon
1. Check the sealing time settings
Correct
Machine does not close
1. Pressure or temperature is not
correct
2. Swivel arm is not in final posi
-
tion
3. Contact switch is not correctly
positioned
Check
Bring swivelling arm
back to end position
Correct
Insufficient adhesion
of patches, label tapes,
labels or fixing of the
transfers
1. Press time too short
2. Incorrect pressure
3. Heating plate too cold
4. Press pad of lower plate worn
out
5. Teflon below heating plate dirty
or
worn
Increase time settings
by 2 seconds and check
results
Set pressure correctly
with knob and check
results
Check temperature
Replace
Clean with soft cloth or
replace
The colour of the textile
penetrates the transfer
1. Temperature set too high
2. Pressure set too high
3. Sealing time set too long
Follow heat sealing in-
structions carefully
Содержание NL-15 R/SQR MAMMOTH
Страница 19: ...thermopatch com 19 Drawing 01...
Страница 21: ...thermopatch com 21 Drawing 02...
Страница 23: ...thermopatch com 23 Drawing 03 for NL 15 R...
Страница 25: ...thermopatch com 25 Drawing 03 for NL 15 SQR...
Страница 28: ...thermopatch com 28 Drawing 04...
Страница 30: ...thermopatch com 30 Drawing 05...
Страница 32: ...thermopatch com 32 Drawing 05A HIGH MODEL 2019 onwards...
Страница 34: ...thermopatch com 34 Drawing 06 pneutics schematics...
Страница 35: ...thermopatch com 35 Drawing 07 Electrical schematics...