6.5 Change settings
6.5.1 Temperature settings
The default operating temperature of 204 °C has been set by
the manufacturer. In case you want to adjust the operating
temperature above or below the default temperature range,
please contact the service department of your supplier.
The default temperature range is: minimum 25 °C, maximum
210 °C.
Temperature change
You can change the temperature in steps of 1 degree by pushing the temperature button 1 x
pushing the + and the -.
You change from Celsius to Fahrenheit and vice versa by pushing the temperature button for
3 seconds.
Temperature check
The temperature is displayed digitally by pressing one key.
An additional check of the temperature between the press plates can be performed by
means of temperature indication labels.
To check the temperature, do the following:
• Let the machine heat up for about 1 minute.
• Set the time to 12 seconds and close the machine.
• After opening the machine again, put the indicator on the press pad and close the
machine again.
• Take the label away immediately after opening the machine.
• For details: https://www.thermopatch.com/en/products/temperature-indicator-labels-
thermolabels/
6.5.2 Pressure settings
The standard factory setting for pressure is set at 5 bar. The pressure is easily set to your
requirements by turning the air pressure adjustment knob of the air pressure regulator
placed on the back of the machine. The adjusted pressure setting will be on display. The NL-
15 R / SQR has a pressure guard which is set to a minimum of 2,5 and a maximum of 6,0
bar. At too low or too high pressure the machine cannot be operated and a failure code will
be on display(4 or 5).
The setting of the lower limit for the pressure setting is done as follows:
by pushing the pressure icon once, the set lower limit appears on display. This can be ad-
justed by p or -. When the lower pressure limit is set to 0, the the pressure guard-
ing system is de-activated.
The setting of the upper limit for the pressure setting is done as follows:
by pushing the pressure icon twice, the set upper limit appears on display. This can be ad-
justed by p or -.
Содержание NL-15 R/SQR MAMMOTH
Страница 19: ...thermopatch com 19 Drawing 01...
Страница 21: ...thermopatch com 21 Drawing 02...
Страница 23: ...thermopatch com 23 Drawing 03 for NL 15 R...
Страница 25: ...thermopatch com 25 Drawing 03 for NL 15 SQR...
Страница 28: ...thermopatch com 28 Drawing 04...
Страница 30: ...thermopatch com 30 Drawing 05...
Страница 32: ...thermopatch com 32 Drawing 05A HIGH MODEL 2019 onwards...
Страница 34: ...thermopatch com 34 Drawing 06 pneutics schematics...
Страница 35: ...thermopatch com 35 Drawing 07 Electrical schematics...