Contents
PRESENTATION
Summary of Features
2
INSTALLATION
Safety Precautions
4
THX Unit
4
Sensors
4
Alarm Relay
4
Power Connection and Wiring Diagram
5
Battery
5
Wall & Panel Mount
6
Panel Mount diagrams
7
New Email Connectivty Setup
8
THX OPERATION
1.0 Summary Screens
10
1.1 Sensor Summary
10
1.2 Door Summary
11
1.3 Alarm Summary
11
1.4 Daily Min / Max
12
2.0 Channel View
12
3.0 Alarm Settings
13
4.0 Settings
4.1 Set Clock
14
4.2 Alarm Mute Setup
14
4.3 Channel On / Off
15
4.4 Sensor Type
15
4.5 Door ON / OFF
16
4.6 Door Setup
16
4.7 Relay Setup
17
4.8 Relay Normally Closed / Normally
Open Setup
17
4.9 Calibration
18
4.10 Network
19
5.0 Plot
5.1 Current Day
19
5.2 History
20
6.0 Service Screen
6.1 Test
21
6.2 Contrast
21
6.3 Keypad
21
6.4 Relay
22
7.0 Language Select
22
8.0 Sample Period
23
9.0 Unit Information
23
10.0 Diagnostics
10.1 Databank
24
10.2 Channel
24
USB
1.
Download Data
25
2.
Download Setup
26
3.
Upload Setup
26
4.
Service
26
WEB SERVER
27
1.
Live Data
28
2.
Status
28
3.
Setup
29
4.
User
30
5.
Time
30
6. Graph
31
7.
Network
31
SPECIFICATION
32
Presentation
SUMMARY OF FEATURES
Datalogger
• Temperature /humidity from each Channel can be set to
sample every 1/5/15/30/60 minutes and stored to an internal
databank
• Up to 12 channels of data logging can be employed using the
module configuration
• Power Supply 100 – 240V AC Mains
• Contents of internal databank can be transferred to the USB
Flash Memory and viewed or transferred to the PC via website
• Universal panel mount or wall mount box
• Expandable modular design
• IP54 Rated
• Battery Back-up up to 6hrs
• Backward compatible with old sensors (PT 100 terminated
with RJ 11)
• EN12830 certified
• CE tested
• On Board Web Server (IP addressable)
• Large data storage capacity
• USB Firmware Upgrade Functionality
• Module Auto-Detect and self-configuration
• Door Alarm Configuration Function (4 doors per module)
Alarm
• 2-Stage high and low level alarms with mute facility
• Stage 1 temperature threshold with trigger delay
• Stage 2 limit temperature with immediate trigger
• Alarm history record for low alarm, high alarm and power fail
• Battery back-up for power-fail operation
• Summary screen for Alarm Overview
Note:
The information supplied in this manual is for guidance only – no part
of this may be used for any agreement, whether express or implied, or to
form any contract.