background image

Temp

Control

 

|

 27 

26 

|

 

Temp

Control

USB

Web Server

2.  Download Setup

From the Main Screen, press the           key, followed by the           key to select Download Setup in the menu and then confirm selection 
 
using the           key to start download the settings. Do not remove the memory stick until the progress bar disappears. 
The data is saved to a file in ‘setup.txt’ format.

3.  Upload Setup

From the Main Screen, press the           key, followed by the           key to select Upload Setup in the menu and then confirm selection 
 
using the           key to start upload previously downloaded settings from the memory stick. Do not remove the memory stick until the 
progress bar disappears. 

4. Service

For use only by authorised personnel and trained installers. 

OK

OK

OK

OK

To connect with unit’s embedded Web Server, connect unit to the network (switch, hub, router etc.) using Ethernet CAT-5 cable or directly 
to the network adapter on your computer and open a web browser - Windows Internet Explorer (version 8.0 or higher) or Firefox. Input the 
unit’s IP address (default -192.168.0.2), see section 4.10. 

Network connection

Direct connection

 

Enter the username and password (as provided below). 

Default username and password:

User: user

Password: password

Содержание THX-DL

Страница 1: ...USER INSTALLATION MANUAL V3 2016 www thermomax refrigeration com THX DL Data Logger Refrigeration...

Страница 2: ...sentation SUMMARY OF FEATURES Datalogger Temperature humidity from each Channel can be set to sample every 1 5 15 30 60 minutes and stored to an internal databank Up to 12 channels of data logging can...

Страница 3: ...of lengths If the sensors need to be extended but factory made extenders are not available they can be extended using a suitable 3 or 4 core cable according to the diagram shown below Please note howe...

Страница 4: ...tied in it It will not be possible to push the cord into the device to such an extent that it will cause a hazard Should the cord insulation fail in an anchorage that has metal parts none of the expo...

Страница 5: ...so be sent in the event of loss of power from the THX DL It is the customers responsibly to keep power to the network infrastructure March 2015 3 How do I test the new Email feature Brief Set up summa...

Страница 6: ...mmary Screen This screen displays the current temperature humidity readings of each of the connected channels and indicates if that channel is in alarm or not The key will return the user to the previ...

Страница 7: ...daily maximum and minimum temperature which are reset at midnight 3 0 ALARM SETTINGS From the Main Screen press the key to select Alarms Settings from the main menu Confirm selection using the key to...

Страница 8: ...se press key If a channel is switched off the alarm parameters will automatically revert back to the default factory settings to prevent an alarm occurrence These parameters cannot be changed until th...

Страница 9: ...ain Screen press the key to select Settings from the main menu Confirm selection using the key to reveal the Settings Menu Scroll down using the key to the second page of the menu select Relay Setup f...

Страница 10: ...om the main menu Confirm selection using the key to reveal the Settings Menu Scroll down using the key to the second page of the menu select Network from the menu and press the key to confirm Please e...

Страница 11: ...ct the date and press the key to confirm Display the door information by selecting SHOW DOOR from the pop up menu and pressing the key to confirm View the information of any door by using the keys 6 0...

Страница 12: ...m the main menu Confirm selection using the key The language used by the THX to communicate the information may be selected here i e English German or French Use the or key to select the required lang...

Страница 13: ...urrently selected channel The MODULE window shows the number of the currently selected module The INPUT TYPE window shows which type of sensor is being used The CALIB DATA window shows calibration val...

Страница 14: ...ey to start upload previously downloaded settings from the memory stick Do not remove the memory stick until the progress bar disappears 4 Service For use only by authorised personnel and trained inst...

Страница 15: ...ontrol Web Server Web Server 1 Live Data Live data screen displays the current temperature humidity readings of each of the connected channels and indicates if that channel is in alarm or not The stat...

Страница 16: ...e To change the date and time use the and click on the button to save the changes 6 Graph Graph screen allow user to generate multiple channel graph To generate the graph set the date choose the chann...

Страница 17: ...t 100mm depth 180mm weight 1 4kg sensor each 0 13kg Box Material Plastic Display Large LCD with backlight SENSORS Type SX PT 100 Platinum Film Compensation 3 wire compensated Cable Length A variety of...

Страница 18: ......

Страница 19: ...ght to alter specifications and drawings without prior notice Issue No 3 July 2016 019264 Head Office Kingspan Environmental 180 Gilford Road Portadown Co Armagh BT63 5LF Tel 44 0 28 3836 4400 UK Sale...

Отзывы: