THERMOBILE INDUSTRIES BV
INSTRUCTIONMANUAL PELLETHEATER
9
Hot
Some surfaces may be hot! Wait until these parts have cooled down before carrying out any
maintenance.
Suggestions and tips to facilitate the necessary tasks or actions.
1.2
Lifting instructions (Fig. 2)
A
Lifting hooks
B
Shafts for lifting using a fork-lift truck
Warning
Do not use any unsuitable material for lifting the convector heater.
To find out the weight of the convector heater, refer to table C in the Appendix at the back of
this manual.
1.3
Icons on the burner (Fig. 3)
A
Switch for manual turning on the ash auger.
B Burner connection
C
Burner fixation
To take out the burner disconnect B and C.
1.4
Use this product for the purpose it was intended for
The convector heater was designed for the heating of tents, building sites, showrooms,
sports halls, storage sheds, workshops, round-the-clock projects, warehouses, greenhouses,
polytunnels, spray arrangements, and for the drying of agricultural produce and bulbs.
1.5
General instructions Warning
•
Make sure to read this manual carefully before using the convector heater.
•
Keep this document near the convector heater.
•
Follow the procedures described.
•
Do not lean on the convector heater.
•
Keep at least 2 meters away from the exhaust opening of the convector heater.
•
Make sure there is sufficient air for proper combustion.
•
Make sure there is no highly flammable material near the convector heater.
•
Make sure that the convector heater has cooled off sufficiently and that the plug has
been removed from the socket before carrying out any repair or maintenance work.
2
INTRODUCTION
2.1
Purpose
This convector heater is an indirectly fired heater with safety thermostat protection,
connections for a room thermostat, and a flue with rain cover.
The convector heater has been tested at sea level at a temperature of 20 C.
2.2
Working principle
Using the selection switch, the convector heater can be used in one of two ways:
•
Position 1: the fan will switch on to supply ventilating air to the room only.
•
Position 2: the burner will switch on, after which the fan will switch on as well, after a
short while. The hot air can be conveyed to the room to be heated by means of a system of
channels or tubes.
Содержание IMAC 2000 PELLET
Страница 2: ...THERMOBILE INDUSTRIES BV INSTRUCTIONMANUAL PELLETHEATER 2 A B C Fig 1 Fig 2 Fig 3 Fig 4 ...
Страница 3: ...THERMOBILE INDUSTRIES BV INSTRUCTIONMANUAL PELLETHEATER 3 ...
Страница 21: ...THERMOBILE INDUSTRIES BV INSTRUCTIONMANUAL PELLETHEATER 21 APPENDIX E ...