THERMOBILE INDUSTRIES BV
INSTRUCTIONMANUAL PELLETHEATER
20
APPENDIX D.
SCHELLINGER / Vacuum system pellet mole/silo with extraction screw.
Instruction manual suction unit page 10-16
NO Unit
Function / discription
DEFAULT THERMOBILE
1
Sec
Suction lead time
5
5
2
Sec
Suction time
40
?!
3
Sec
Suction following time
10
10
4
Sec
Pause time
10
10
5
Min
Max filling time
60
60
6
-
Pause time between fillings
3
30
7
Sec
Run period extraction motor direction 2
1
1
8
Sec
Pause time extraction motor direction 2
1
1
9
-
Number of repetition cycle 2
3
3
10
h/min
Time unit of parameter pause time in hours
or minutes 0=min 1=hours
1
0
Par 2 must be set according to the length of the extraction system. If this time is set to
long there will be too much pellets in the cyclone separator. In that case the filter will be
blocked. This can lead to equipment damage.
Set active timer:
Thermobile will program this time standard: 0:01h – 23:59h. This means that the suction
unit is active between 0.01h and 23.59h (And will be in rest for 2 minutes between 23.59
and 0.01h)