The figure below shows a typical pattern of electrical wiring devices protection belt.
Electrical connections must be executed by conduit or flexible, through cable gland
installed on the device frame. To keep the original degree of protection, tha cable gland
should have the following features:
• Degree of protection IP65 minimum;
• Cable gland gasketed;
• Thread as indicated in Tab. 3-1.
For details of electrical connections, refer to Annexes who are in the back of the manual;
ensure that once installed, the cable glands are locked firmly on the housing. In
accordance with current legislation, the housing must be grounded through ground wire to
appropriate section.
4.5
ATEX: Safety informations for use in Explosive Atmospheres.
European directives (ATEX 2014/34/UE) for equipment and 1999/92/CE for the workplace
(plant), establishing the essential safety requirements against the risk of explosion in
hazardous areas; refer to these guidelines for more details on 'use and installation.
WARNING
Before installation in hazardous areas classified according to directives ATEX, you
must verify that the product is appropriate for the zone classification and
characteristics of flammable substances.
19 / 30
Cod.: PL-000603X-D002G
Содержание PRO-LINE 60-30G
Страница 25: ...8 ANNEX 25 30 Cod PL 000603X D002G ...
Страница 26: ...26 30 Cod PL 000603X D002G ...
Страница 27: ...27 30 Cod PL 000603X D002G ...
Страница 28: ...28 30 Cod PL 000603X D002G ...
Страница 29: ...29 30 Cod PL 000603X D002G ...
Страница 30: ...30 30 Cod PL 000603X D002G ...