Normal Controller Operation
6-2
Thermo Scientific
This chapter provides brief instructions on how to perform the following
configuration changes:
• Setting the temperature
• Setting the Over-temperature Protection Temperature
• Changing between celsius and fahrenheit
• Setting the ramp to setpoint time
• Autotuning the controller
Detailed instructions on configuring the temperature controller are found in the
UT150 operation manual.
For instructions on the Controller -PC Communication Option, refer to
.
Normal Controller Operation
The Temperature Controller senses the chamber air temperature of the furnace
(the PV, or process value) and supplies the heat necessary to achieve the desired
setpoint. The controller includes an LED display and a push button keypad. Refer
for lists of displayed parameters and keypad
functions.
Table 2. UT150 Parameter Functions
Operating Parameters (access by holding the SET/ENT button)
Parameter code
Factory
set value
Description
A1
1225.0
Alarm Setpoint (°C,2237 °F)
CtL
Pid
Control mode
At
oFF
Auto tuning
P
20.0
Proportional band (°C, °F=16.2)
I
120
Integral time
d
30
Derivatives time
Ct
1
Heat cycle time
FL
oFF
Sensor filter
bS
0.0
PV bias (offset)
Loc
0
Key loc
Setup parameter (access by setting LoC = “-1”)
Содержание BF51841BC
Страница 1: ......
Страница 6: ...List of Figures ii Thermo Scientific ...
Страница 18: ...Safety Notes Standards and Directives 1 12 Thermo Scientific ...
Страница 22: ...Unpacking Unpacking 3 2 Thermo Scientific ...
Страница 28: ...Installation Shelf Installation in Box Furnaces 4 6 Thermo Scientific ...
Страница 38: ...Correction of Temperature Overshoot 6 8 Thermo Scientific ...
Страница 42: ...Excess Temperature Option B Model Excess Temperature Controller Operation 7 4 Thermo Scientific ...
Страница 48: ...Communication Option Addresses for Multiple Controllers 8 6 Thermo Scientific ...
Страница 55: ...Maintenance Door Insulation Replacement Thermo Scientific 9 7 Figure 11 Door Insulation Replacement ...
Страница 57: ...Maintenance Right Hand Door Conversion Thermo Scientific 9 9 Figure 12 Door Hinge Sheet 2 2 ...
Страница 63: ...Replacement Parts Thermo Scientific 11 3 Figure 13 Wiring Diagram ...
Страница 64: ...Replacement Parts 11 4 Thermo Scientific ...
Страница 65: ...Thermo Scientific 12 1 12 Error Codes This chapter is not applicable ...
Страница 66: ...Error Codes 12 2 Thermo Scientific ...
Страница 68: ...WEEE Compliance 13 2 Thermo Scientific ...
Страница 69: ...Thermo Scientific 14 1 14 14 Spare Parts and Accessories This chapter is not applicable ...
Страница 70: ...Spare Parts and Accessories 14 2 Thermo Scientific ...
Страница 72: ...Device Log 15 2 Thermo Scientific ...