Radio Options
AutoWAVE Radio Option
7-6 AutoPILOT PRO Flow Computer User Guide
Thermo Fisher Scientific
3.
Connect the coaxial ground to the enclosure ground stud using the
coaxial ground hardware provided.
4.
Mount an N-type panel mount jack or optional coaxial protector on
the bottom of the enclosure, and connect it to the radio antenna output
through a coaxial cable and an SMA plug.
5.
Connect the cable assembly (p/n 3-0500-075) from the radio’s 10-pin
connector to the computer's host port (TB16 on the main board) or
other RS232 device. If connecting to TB16, return the main board and
mounting bracket to the down position. Connections to TB16 are
shown in the table below.
Table 7–3. AutoWAVE radio cable assembly to TB16 connections
Color
Radio 10-Pin Connector
TB16 on Main Board
White
5
TB16-1 (RX)
Black/Shield
6
TB16-8 (GND)
Green
7
TB16-3 (TX)
Blue
10
TB16-5 (DCD)
Orange
Jumper
TB16-2 (CTS)
Orange
Jumper
TB16-4 (RTS)
6.
For power, connect the cable from the radio to TB12 on the main
board as shown in the table below.
Table 7–4. AutoWAVE radio power to TB12 connections
Color
AutoWAVE Radio
TB12 on Main Board
Red
+BAT
TB12-1 (VRadio1)
Black
GND
TB12-2 (GND)
7.
If necessary, return the main board and mounting bracket to the down
position. Tighten the thumbscrews, and shut the enclosure door.