Thermo Fisher Scientific
AutoPILOT PRO Flow Computer User Guide 10-1
Chapter 10
Functional Description
This chapter provides a functional description of the instrument. For
additional details, such as instructions on configuring calculations or
performing calibrations, refer to the AutoCONFIG software help system.
The AutoPILOT PRO flow computer provides support for differential
pressure meter and linear meter types. For differential pressure meters, the
instrument supports orifice, V-Cone, annubar, and slotted DP installations.
For linear meters, the instrument supports turbine and ultrasonic
installations.
The following equations are used in combinations specified by the AGA.
Supercompressibility is run once per second for all meter runs. Users may
select from the following regardless of the meter type:
AGA 8 Gross Method – 1992
AGA 8 Detail Method – 1992
AGA 8 Short Form – 1985
NX-19
NX-19 Analysis
GERG
Flow Computer
Tasks
Meter Types
Equations
Supercompressibility