1-2
Cooling and Heating Capacity
Specifications
CRR-20 & CRR-40, September 1999
Heater Type
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
Heating Capacity
Heating Capacity
Watts
Kcal/hr
BTU/hr
Watts
Kcal/hr
BTU/hr
CRR-20SL*
5,560
4,780
18,975
4,110
3,535
14,025
CRR-40* 5,880
5,060
20,070
4,900
4,215
16,720
CRR-20SL & CRR-40 Models*
*System net heating capacity for all models includes electric resistance rods and fan heat.
Return air to
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
evaporator
Net Cooling Capacity
Power Consp
Net Cooling Capacity
Power Consp
coil inlet
Watts
Kcal/hr
BTU/hr
kW @460V
Watts
Kcal/hr
BTU/hr
kW @460V
1.7 C (35 F)
12,900
11,095
44,030
9.8
10,746
9,242
36,675
8.2
-17.8 C (0 F)
6,300
5,418
21,500
5.1
5,250
4,515
17,920
4.2
CRR-40 Models with Three Evaporator Fans — Water Cooled Condensing Option with 30 C
(86 F) Water Temperature*
*System net cooling capacity with a 30 C (86 F) water temperature, 30 liter/min. (8 gal./min.) water flow and R-134a.
Return air to
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
evaporator
Net Cooling Capacity
Power Consp
Net Cooling Capacity
Power Consp
coil inlet
Watts
Kcal/hr
BTU/hr
kW @460V
Watts
Kcal/hr
BTU/hr
kW @460V
1.7 C (35 F)
10,900
9,375
37,200
10.2
9,080
7,810
30,990
8.5
-17.8 C (0 F)
5,600
4,816
19,115
5.3
4,665
4,010
15,925
4.4
CRR-40 Models with Three Evaporator Fans — Water Cooled Condensing Option with 37.8 C
(100 F) Water Temperature*
*System net cooling capacity with a 37.8 C (100 F) water temperature, 30 liter/min. (8 gal./min.) water flow and R-134a.
System Net Cooling Capacity — Full Cool (Continues)
System Net Heating Capacity
Содержание CRR-20