CRR-20 & CRR-40, September 1999
1
Specifications
Return air to
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
evaporator
Net Cooling Capacity
Power Consp
Net Cooling Capacity
Power Consp
coil inlet
Watts
Kcal/hr
BTU/hr
kW @460V
Watts
Kcal/hr
BTU/hr
kW @460V
1.7 C (35 F)
11,450
9,850
39,100
10.5
9,540
8,205
32,570
8.7
-17.8 C (0 F)
5,605
4,820
19,125
6.6
4,670
4,015
15,930
5.5
-28.9 C (-20 F)
3,025
2,600
10,300
4.5
2,520
2,165
8,580
3.7
CRR-40 Models with Three Evaporator Fans — Air Cooled Condensing*
*System net cooling capacity with a 37.8 C (100 F) ambient air temperature and R-134a.
Return air to
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
evaporator
Net Cooling Capacity
Power Consp
Net Cooling Capacity
Power Consp
coil inlet
Watts
Kcal/hr
BTU/hr
kW @460V
Watts
Kcal/hr
BTU/hr
kW @460V
1.7 C (35 F)
11,750
10,105
40,100
10.4
9,750
8,390
33,280
8.6
-17.8 C (0 F)
6,005
5,170
20,500
5.7
4,985
4,290
17,015
4.7
-28.9 C (-20 F)
3,105
2,670
10,600
4.3
2,580
2,220
8,800
3.6
CRR-40 Models with Two Evaporator Fans — Air Cooled Condensing*
*System net cooling capacity with a 37.8 C (100 F) ambient air temperature and R-134a.
Return air to
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
evaporator
Net Cooling Capacity
Power Consp
Net Cooling Capacity
Power Consp
coil inlet
Watts
Kcal/hr
BTU/hr
kW @460V
Watts
Kcal/hr
BTU/hr
kW @460V
1.7 C (35 F)
9,320
8,015
31,800
8.2
7,765
6,675
26,490
6.8
-17.8 C (0 F)
4,300
3,700
14,675
4.6
3,580
3,080
12,225
3.8
-25.0 C (-13 F)
3,000
2,580
10,240
4.2
2,500
2,150
8,530
3.5