INSTOMAX

TM

 Integrated instantaneous water heater installation, use and care manual 

(Revision Sept  2013)

,  

Page 

10.

 

exchanger  containing  potable  water  must  be 
filled. 
 
Make sure  that the heat exchanger  drain cock is 
turn off. 
 
Open the nearest domestic hot water tap as well 
as  any  control  valve  on  the  water  heater  outlet 
(the copper tube at top the water heater). 
 
The cold water supply to the unit shall be Open.  
 
Close  the  domestic  hot  water  tap  as  soon  as 
water flows out of it. Fix any leaks 
 
Open  every  other  hot  water  domestic  hot  water 
paps  in  succession,  in  order  to  evacuate  aire 
from the distribution system. 

 
4.4 

TANK 

THERMAL 

MASS 

FLUID 

(WATER) 

AQUASTAT 

TEMPERATURE 

SETTING 

 
Consider  safety  and  energy  saving  while  setting 
the water heater tank temperature aquastat(s). It 
is  more  energy  efficient  to  set  the  tank 
temperature as low as possible. But lowering the 
temperature  results  in  less  storage  of  energy  to 
provide domestic hot  water heater.  
 
A  minimum  of  70°C  (160°F)  tank  temperature 
is recommended  as  a  starting  point  to  insure 
a good supply of domestic hot water.
  
 
To  adjust  the  temperature  set  point  of  the 
aquastat turn the knob until the required value of 
the  desired  temperature  is  aligned  with  the 
reference point. 

 

 

 
In  usage,  it  may  be  found  that  the  set  tank 
temperature  needs  to  be  increase  in  order  to 
supply all the domestic water needs. The tank set 
temperature  may  be  raised  up  to  a  maximum  of 
88°C (190°). 

 
If  the  unit  has  two  aquastats,  set  one  of  them 
approximately 2C (5F) lower then the other one. 
 

4.5 START UP PROCEDURE          
 

1.  Fill  tank  and heat exchanger as  described  in 

sections 4.2 and 4.3. 

2.  Adjust  temperature  levels  as  described  in 

section 4.4 

3.  Turn ON the water heater electric breaker. 
4.  The  water  heater  main  contactor  should 

close  with  an  audible  snap  sound,  and  all 
elements  should  turn  on,  along  with  their 
indicator light.  

5.  Tank  temperature  should  gradually  increase. 

Time  required  for the INSTOMAX™  to reach 
the  tank  water  temperature  set  point  vary 
from  1  to  4  hours  according  to  the  water 
heater power input. 

6.  Once  the  temperature  set  point  is  reach, 

heating  elements  and  their  indicator  light  will 
turn off. 

 
4.6  THERMOSTATICALLY  CONTROLLED 
MIXING VALVE SETTING 

A  thermostatically  controlled 

mixing 

valve 

automatically  regulates    the  mix  of  very  hot  and 
cold  water  as  required  to  provide  safe  domestic 
hot water under variable conditions. 
 
To adjust the mixing valve setting, carefully open 
a  hot  water  tap.  Protect  yourself  against  the 
scalding. Measure the hot water temperature with 
a  thermometer.  Mixing  valve  adjustment  is 
achieved  by  turning  the  mixing  valve  knob 
clockwise  to  reduce  the  domestic  water 
temperature, 

contraclockwise 

to 

raise 

the 

domestic water temperature, 
 
Unless  local  regulation  requires  otherwise,  a 
50°C (120°F) is considered the best temperature 
to  reduce  heat  loss  through  the  plumbing  and 
prevent scalding for young kid and senior citizen. 
Generally  residential  dishwasher  are  provided 
with  their  own  water  heating  element  and  don’t 
required hotter water. 
 
Raising 

the 

domestic 

hot 

water 

outlet 

temperature  will  not  provide  more  domestic  hot 
water.  In  order  to  provide  more  domestic  hot 
water,  the  amount  of  energy  in  the  water  heater 
tank  need  to  be  increase,  this  is  achieved  by 
increasing the water tank temperature (maximum 
88°C /190°). 

Reference point 

Содержание INSTOMAX 12

Страница 1: ...nd maintenance of the boiler in order to insure your full satisfaction Installer and user MUST read carefully and understand these instructions Any questions regarding the operation maintenance service or warranty of this appliance should be directed to the dealer or distributor you purchased it from When all installation steps have been completed replace this installation manual in its original e...

Страница 2: ...5 25 6 1x4 5 1x3kW 31 8 6 40 INSTOMAX 9 9 30 7 2x4 5kW 38 8 6 50 INSTOMAX 12 12 41 2x6kW 50 6 6 70 Can also be connected to a 208V 1ph source This would provide 75 of the nominal capacity at 240V Suggested Local code regulations and authority having jurisdiction may require different wiring and fuses Maximum operating pressure on the tank 207kPa 30psi Tank temperature range 10o C to 90o C 50o F to...

Страница 3: ...ition of the National Plumbing Code and the National Electric Code In any case where instructions in this manual differ from local or national codes the local or national codes take precedence 2 3 CORROSIVE ATMOSPHERE The water heater should not be located near an air supply containing halogenated hydrocarbons or high humidity Such localisation would void any water heater warranty 2 4 SHIPMENT INS...

Страница 4: ...ect to physical damage for example by moving vehicles area flooding etc All models can be installed on combustible floors and in alcoves If the water heater is to be installed in a restaurant or other location where the floor is frequently cleaned it must be elevated to provide at least 150mm 6 inches of clearance from the floor to comply with NSF International recommendations The room temperature...

Страница 5: ...ated instantaneous water heater installation use and care manual Revision Sept 2013 Page 5 Figure 1 Top view components identification and their location Figure 2 Front view components identification and their location ...

Страница 6: ...the water heater right side HOT WATER OUTLET and COLD WATER INLET 3 4 NPT FEM fittings are use for connections Use only clean new pipe for domestic water connection Local codes regulations and authorities having jurisdiction may required specific pipe material to be used for connections Insulate all pipes containing hot water especially in unheated areas A thermometer should be installed to indica...

Страница 7: ...lled mixing valve This valve allows reducing setting and regulating the domestic hot water temperature at a safe level In order to adjust the mixing valve to the desire temperature create a demand for domestic hot water measuring the domestic hot water temperature will indicate the adjustment required 3 6 ELECTRICAL 3 61 Main electrical power supply The water heater electrical wiring and grounding...

Страница 8: ...INSTOMAXTM Integrated instantaneous water heater installation use and care manual Revision Sept 2013 Page 8 ...

Страница 9: ...jury and may be used as a guide in determining the safest water temperature for your applications TIME TO SCALDING VS TEMPERATURE RELATIONSHIP Temperature Time to scalding 50 C 120 F Over 5 minutes 52 C 125 F 1 1 2 to 2 minutes 54 C 130 F About 30 seconds 57 C 135 F About 10 seconds 60 C 140 F Less than 5 seconds 63 C 145 F Less than 3 seconds 66 C 150 F About 1 1 2 second 68 C 155 F About 1 secon...

Страница 10: ...heat exchanger as described in sections 4 2 and 4 3 2 Adjust temperature levels as described in section 4 4 3 Turn ON the water heater electric breaker 4 The water heater main contactor should close with an audible snap sound and all elements should turn on along with their indicator light 5 Tank temperature should gradually increase Time required for the INSTOMAX to reach the tank water temperatu...

Страница 11: ...ker before attempting any work on the water heater Visual inspection of the water heater electrical cabinet Checks for leaks at the heating elements sign of overheating of electrical components and wiring Check for t proper operation of the unit temperature control Check the thermostatic mixing valve proper operation by measuring domestic water temperature at a domestic hot water tap with a thermo...

Страница 12: ...anty is void and shall not apply if A Defects or malfunctions resulting from installation repair maintenance and or usage that are not done in conformity with the manufacturer s installation manual or B Defects or malfunctions resulting from installation maintenance or repair that are not done in accordance with regulations in force or C Defects or malfunctions resulting from improper installation...

Отзывы: