background image

 

INSTOMAX

TM

 Integrated instantaneous water heater installation, use and care manual 

(Revision Sept  2013)

,  

Page 

2.

 

Section 1: Technical specifications

 

Table 1: Boiler / heater specification 240*V/1PH (2 leads2) : 

Suggested 

conductor size  

Model 

Input 

Heating 

Current 

draw 

at 240V** 

Suggested 

fuse 

  

kW/Mbtu  

Elements  

à 240v 

cu 

al 

size** 

INSTOMAX 4.5 

4,5 / 15,3 

1 x 4,5kW 

19 

12 

10 

25 

INSTOMAX 6 

6 / 20.5 

1 x 6kW 

25 

40 

INSTOMAX 7.5 

7,5 / 25,6 

1x4.5+1x3kW 

31 

40 

INSTOMAX 9 

9 / 30,7 

2x4,5kW 

38 

50 

INSTOMAX 12 

12 / 41 

2x6kW 

50 

70 

*Can also be connected to a 208V/1ph source. This would provide  75% of the nominal capacity at 240V 
**Suggested. Local code, regulations and authority having jurisdiction may require different wiring and 
fuses. 

 

Maximum operating pressure on the tank: 207kPa / 30psi 
 
Tank temperature range : 10

o

C to 90

o

C (50

o

F to 190

o

F) 

 

Table 2 : Dimensions: 

Height :     1537mm (60-1/2’’) 
With :          559mm (22’’) 
Depth :          648mm (25-1/2’’)  
Water connections : 

o

  Supply fresh water inlet :     3/4"NPT Fem. 

o

  Domestic hot water outlet :  3/4"NPT Fem. 

o

  Expansion tank outlet :        1/2"NPT M. 

 

 

 

 

Содержание INSTOMAX 12

Страница 1: ...nd maintenance of the boiler in order to insure your full satisfaction Installer and user MUST read carefully and understand these instructions Any questions regarding the operation maintenance service or warranty of this appliance should be directed to the dealer or distributor you purchased it from When all installation steps have been completed replace this installation manual in its original e...

Страница 2: ...5 25 6 1x4 5 1x3kW 31 8 6 40 INSTOMAX 9 9 30 7 2x4 5kW 38 8 6 50 INSTOMAX 12 12 41 2x6kW 50 6 6 70 Can also be connected to a 208V 1ph source This would provide 75 of the nominal capacity at 240V Suggested Local code regulations and authority having jurisdiction may require different wiring and fuses Maximum operating pressure on the tank 207kPa 30psi Tank temperature range 10o C to 90o C 50o F to...

Страница 3: ...ition of the National Plumbing Code and the National Electric Code In any case where instructions in this manual differ from local or national codes the local or national codes take precedence 2 3 CORROSIVE ATMOSPHERE The water heater should not be located near an air supply containing halogenated hydrocarbons or high humidity Such localisation would void any water heater warranty 2 4 SHIPMENT INS...

Страница 4: ...ect to physical damage for example by moving vehicles area flooding etc All models can be installed on combustible floors and in alcoves If the water heater is to be installed in a restaurant or other location where the floor is frequently cleaned it must be elevated to provide at least 150mm 6 inches of clearance from the floor to comply with NSF International recommendations The room temperature...

Страница 5: ...ated instantaneous water heater installation use and care manual Revision Sept 2013 Page 5 Figure 1 Top view components identification and their location Figure 2 Front view components identification and their location ...

Страница 6: ...the water heater right side HOT WATER OUTLET and COLD WATER INLET 3 4 NPT FEM fittings are use for connections Use only clean new pipe for domestic water connection Local codes regulations and authorities having jurisdiction may required specific pipe material to be used for connections Insulate all pipes containing hot water especially in unheated areas A thermometer should be installed to indica...

Страница 7: ...lled mixing valve This valve allows reducing setting and regulating the domestic hot water temperature at a safe level In order to adjust the mixing valve to the desire temperature create a demand for domestic hot water measuring the domestic hot water temperature will indicate the adjustment required 3 6 ELECTRICAL 3 61 Main electrical power supply The water heater electrical wiring and grounding...

Страница 8: ...INSTOMAXTM Integrated instantaneous water heater installation use and care manual Revision Sept 2013 Page 8 ...

Страница 9: ...jury and may be used as a guide in determining the safest water temperature for your applications TIME TO SCALDING VS TEMPERATURE RELATIONSHIP Temperature Time to scalding 50 C 120 F Over 5 minutes 52 C 125 F 1 1 2 to 2 minutes 54 C 130 F About 30 seconds 57 C 135 F About 10 seconds 60 C 140 F Less than 5 seconds 63 C 145 F Less than 3 seconds 66 C 150 F About 1 1 2 second 68 C 155 F About 1 secon...

Страница 10: ...heat exchanger as described in sections 4 2 and 4 3 2 Adjust temperature levels as described in section 4 4 3 Turn ON the water heater electric breaker 4 The water heater main contactor should close with an audible snap sound and all elements should turn on along with their indicator light 5 Tank temperature should gradually increase Time required for the INSTOMAX to reach the tank water temperatu...

Страница 11: ...ker before attempting any work on the water heater Visual inspection of the water heater electrical cabinet Checks for leaks at the heating elements sign of overheating of electrical components and wiring Check for t proper operation of the unit temperature control Check the thermostatic mixing valve proper operation by measuring domestic water temperature at a domestic hot water tap with a thermo...

Страница 12: ...anty is void and shall not apply if A Defects or malfunctions resulting from installation repair maintenance and or usage that are not done in conformity with the manufacturer s installation manual or B Defects or malfunctions resulting from installation maintenance or repair that are not done in accordance with regulations in force or C Defects or malfunctions resulting from improper installation...