background image

 

INSTOMAX

TM

 Integrated instantaneous water heater installation, use and care manual 

(Revision Sept  2013)

,  

Page 

3.

 

      

General Safety Precautions

 

 

Make  sure  to  read  and  understand  the  entire  Installation,  Use  and  care  Manual  before 
attempting to install or operate this  INSTOMAX

MC

 water heater. Pay particular attention to the 

following “General Safety Precaution”. Failure to follow these WARNINGs may cause death, 
bodily  injuries  or  property  damages.  Should  you  have  any  problems  understanding  theses 
instructions STOP and get help from a qualified technician or installer. 

 

Section 2: INTRODUCTION 

 

 

The  important  safeguards  and  instructions 
appearing  in  this  manual  are  not  meant  to 
cover  all  possible  conditions  and  situations 
that may occur. It should be understood that 
common sense, caution  and care are factors 
which  cannot  be  built  into  every  product. 
These  factors  must  be  supplied  by  the 
person(s) caring for and operating the unit. 

 
 
2.1 GÉNERAL INFORMATION 

The  INSTOMAX™  is  an  instantaneous  water 
heater.  It  is  composed  of  a  thermal  mass 
reservoir filled either by water or other liquid and 
a  copper  heat  exchanger  immersed  in  the 
thermal  fluid.  Domestic  fresh  water  passing 
through  the  heat  exchanger  is  heated  by  the 
thermal  fluid.  Therefore  the  INSTOMAX™  has 
two  separate  hydraulic  circuits:  The  reservoir 
(thermal mass) side and the domestic hot water 
side located inside the heat exchanger. 

 
2.2 LOCAL INSTALLATION 
REGULATIONS 

This  water  heater  must  be  installed  in 
accordance  with  these  instructions  and  must 
conform  to  local  codes,  with  the  current  edition 
of the National Plumbing Code and the National 
Electric  Code.  In  any  case  where  instructions  in 
this  manual  differ  from  local  or  national  codes, 
the local or national codes take precedence. 
 

2.3 CORROSIVE ATMOSPHERE 

The water heater should not be  located  near an 
air  supply  containing  halogenated  hydrocarbons 
or  high  humidity.  Such  localisation  would  void 
any water heater warranty.

 

2.4 SHIPMENT INSPECTION 

Upon  reception,  inspect  the  water  heater  for 
possible  shipping  damage.  The  manufacturer’s 
responsibility ceases upon delivery of the goods 
in good condition to the carrier. Consignee must 
file  any  claims  for  damage,  shortage  in 
shipments  or  non-delivery  immediately  against 
the carrier. 
 

2.5 CHECK LIST 

CHECK  the  boiler  identification  plate  to  insure 
that you have received the right model. 

Make  sure  that  the  following  items  are 
included with the water heater: 

  Tank 207 kPa (30 psi) pressure relief valve. 

  Domestic  hot  water  860  kPa  (125  psi) 

pressure relief valve. 

  Tank 

and 

domestic 

hot 

water 

heat 

exchanger drain valve. 

  Thermo  manometer  (heat  and  pressure 

indicator). 

  Automatic air vent. 

  83 kPa (12 psi) tank pressure regulator. 

  Check valve with vacuum breaker. 

  Thermostatic  domestic  water  temperature 

regulator. 

  Electric heating elements and components. 

  Aquastats temperature controller. 

  Heating  circuit  expansion  tank  is  supplied 

with the water heater, but not installed. 

 

 
 
The INSTOMAX

TM

 water heater should not be 

located  in  an  area  where  leakage  from  the 
tank  or  water  connections  will  result  in 
damage  to  the  adjacent  area  or  lower  floors 
of the structure. When such areas cannot  be 
avoided,  a  suitable  drain  pan  or  non-
flammable  catch  pan,  adequately  drained, 
must  be  installer  under  the  boiler.  The  pan 
must be connected to a drain. 

 

WARNING 

 ! 

WARNING 

 ! 

Содержание INSTOMAX 12

Страница 1: ...nd maintenance of the boiler in order to insure your full satisfaction Installer and user MUST read carefully and understand these instructions Any questions regarding the operation maintenance service or warranty of this appliance should be directed to the dealer or distributor you purchased it from When all installation steps have been completed replace this installation manual in its original e...

Страница 2: ...5 25 6 1x4 5 1x3kW 31 8 6 40 INSTOMAX 9 9 30 7 2x4 5kW 38 8 6 50 INSTOMAX 12 12 41 2x6kW 50 6 6 70 Can also be connected to a 208V 1ph source This would provide 75 of the nominal capacity at 240V Suggested Local code regulations and authority having jurisdiction may require different wiring and fuses Maximum operating pressure on the tank 207kPa 30psi Tank temperature range 10o C to 90o C 50o F to...

Страница 3: ...ition of the National Plumbing Code and the National Electric Code In any case where instructions in this manual differ from local or national codes the local or national codes take precedence 2 3 CORROSIVE ATMOSPHERE The water heater should not be located near an air supply containing halogenated hydrocarbons or high humidity Such localisation would void any water heater warranty 2 4 SHIPMENT INS...

Страница 4: ...ect to physical damage for example by moving vehicles area flooding etc All models can be installed on combustible floors and in alcoves If the water heater is to be installed in a restaurant or other location where the floor is frequently cleaned it must be elevated to provide at least 150mm 6 inches of clearance from the floor to comply with NSF International recommendations The room temperature...

Страница 5: ...ated instantaneous water heater installation use and care manual Revision Sept 2013 Page 5 Figure 1 Top view components identification and their location Figure 2 Front view components identification and their location ...

Страница 6: ...the water heater right side HOT WATER OUTLET and COLD WATER INLET 3 4 NPT FEM fittings are use for connections Use only clean new pipe for domestic water connection Local codes regulations and authorities having jurisdiction may required specific pipe material to be used for connections Insulate all pipes containing hot water especially in unheated areas A thermometer should be installed to indica...

Страница 7: ...lled mixing valve This valve allows reducing setting and regulating the domestic hot water temperature at a safe level In order to adjust the mixing valve to the desire temperature create a demand for domestic hot water measuring the domestic hot water temperature will indicate the adjustment required 3 6 ELECTRICAL 3 61 Main electrical power supply The water heater electrical wiring and grounding...

Страница 8: ...INSTOMAXTM Integrated instantaneous water heater installation use and care manual Revision Sept 2013 Page 8 ...

Страница 9: ...jury and may be used as a guide in determining the safest water temperature for your applications TIME TO SCALDING VS TEMPERATURE RELATIONSHIP Temperature Time to scalding 50 C 120 F Over 5 minutes 52 C 125 F 1 1 2 to 2 minutes 54 C 130 F About 30 seconds 57 C 135 F About 10 seconds 60 C 140 F Less than 5 seconds 63 C 145 F Less than 3 seconds 66 C 150 F About 1 1 2 second 68 C 155 F About 1 secon...

Страница 10: ...heat exchanger as described in sections 4 2 and 4 3 2 Adjust temperature levels as described in section 4 4 3 Turn ON the water heater electric breaker 4 The water heater main contactor should close with an audible snap sound and all elements should turn on along with their indicator light 5 Tank temperature should gradually increase Time required for the INSTOMAX to reach the tank water temperatu...

Страница 11: ...ker before attempting any work on the water heater Visual inspection of the water heater electrical cabinet Checks for leaks at the heating elements sign of overheating of electrical components and wiring Check for t proper operation of the unit temperature control Check the thermostatic mixing valve proper operation by measuring domestic water temperature at a domestic hot water tap with a thermo...

Страница 12: ...anty is void and shall not apply if A Defects or malfunctions resulting from installation repair maintenance and or usage that are not done in conformity with the manufacturer s installation manual or B Defects or malfunctions resulting from installation maintenance or repair that are not done in accordance with regulations in force or C Defects or malfunctions resulting from improper installation...