Section 5: MAINTENANCE 

 

5.1 INTRODUCTION  

Regular  water  heater  maintenance  will  ensure 
trouble-free  service  for  many  years.  It  is 
recommended  that  you  set  up  and  follow  a 
maintenance  program.  All  component  may  fail 
eventually.  The  use  of  incorrect  replacement 
parts  or  disregarding  safety  procedures  and 
warnings  during  repairs  may  reduce  the  boiler 
safety level and shorten its useful life. 
 
The  owner  should  set  up  the  following 
maintenance program. 
 

5.2 AT ALL TIMES 

The  water  heater  should  be  immediately 
inspected in case of: 

 

Overheating  or  burn  plastic  odours  are 

detected. 

 

Water  leak  from  the  water  heater  or  the 

domestic hot water system is found. 
 
If the hot water is leaking from the pressure relief 
valve,  it  may  indicate  a  problem  with  some 
components  of the  systems.  Immediate  attention 
and  repair by a qualified technician are required. 
NEVER  CLOSE  OR  PLUG  A  PRESSURE 
RELIEF VALVE. 
 
 

5.3 YEARLY INSPECTION   

 
 
Make sure that the power supply to the water 
heater has been turn off at the circuit breaker 
before  attempting  any  work  on  the  water 
heater. 
 

 

Visual  inspection  of  the  water  heater 

electrical cabinet. Checks for leaks at the heating 
elements,  sign  of  overheating  of  electrical 
components  and  wiring.  Check  for  t  proper 
operation of the unit  temperature control.  

 

Check  the  thermostatic  mixing  valve 

proper  operation  by  measuring  domestic  water 
temperature  at  a  domestic  hot  water  tap  with  a 
thermometer.  

 

Check  for  proper  operation  of  the 

automatic  air  vent,  located  on  top  of  the  water 
heater,  by  removing  its  cap  and  by  pressing  on 
the  knob,  releasing  air  until  water  began  to  be 
expelled.  

 

Do  not  open  the  tank  drain  tap  unless 

repair  to  the  water  heater  is  required.  Opening 
the drain tap will eventually force fresh water into 
the tank. This water will introduce oxygen diluted 
in  the  fresh  water.  This  oxygen  will  cause 
corrosion  of  the  tank  internal  surfaces,  damaged 
the reservoir and void the warranty. 

 

If  repair  is  required,  it  should  be 

accomplished as soon as possible, by a qualified 
technician and using genuine replacement parts. 
 
 
 
 
The  manufacturer’s  warranty  DOES  NOT 
cover 

problems 

caused 

by 

improper 

installation or maintenance. If the safety valve 
opens  periodically,  it  may  be  due  to  the 
expansion  tank.  Immediately  call  a  qualified 
technician to appraise and repair the problem.  
  
 
 

D

 L

DANGER

WARNING 

  ! 

Содержание INSTOMAX 12

Страница 1: ...nd maintenance of the boiler in order to insure your full satisfaction Installer and user MUST read carefully and understand these instructions Any questions regarding the operation maintenance service or warranty of this appliance should be directed to the dealer or distributor you purchased it from When all installation steps have been completed replace this installation manual in its original e...

Страница 2: ...5 25 6 1x4 5 1x3kW 31 8 6 40 INSTOMAX 9 9 30 7 2x4 5kW 38 8 6 50 INSTOMAX 12 12 41 2x6kW 50 6 6 70 Can also be connected to a 208V 1ph source This would provide 75 of the nominal capacity at 240V Suggested Local code regulations and authority having jurisdiction may require different wiring and fuses Maximum operating pressure on the tank 207kPa 30psi Tank temperature range 10o C to 90o C 50o F to...

Страница 3: ...ition of the National Plumbing Code and the National Electric Code In any case where instructions in this manual differ from local or national codes the local or national codes take precedence 2 3 CORROSIVE ATMOSPHERE The water heater should not be located near an air supply containing halogenated hydrocarbons or high humidity Such localisation would void any water heater warranty 2 4 SHIPMENT INS...

Страница 4: ...ect to physical damage for example by moving vehicles area flooding etc All models can be installed on combustible floors and in alcoves If the water heater is to be installed in a restaurant or other location where the floor is frequently cleaned it must be elevated to provide at least 150mm 6 inches of clearance from the floor to comply with NSF International recommendations The room temperature...

Страница 5: ...ated instantaneous water heater installation use and care manual Revision Sept 2013 Page 5 Figure 1 Top view components identification and their location Figure 2 Front view components identification and their location ...

Страница 6: ...the water heater right side HOT WATER OUTLET and COLD WATER INLET 3 4 NPT FEM fittings are use for connections Use only clean new pipe for domestic water connection Local codes regulations and authorities having jurisdiction may required specific pipe material to be used for connections Insulate all pipes containing hot water especially in unheated areas A thermometer should be installed to indica...

Страница 7: ...lled mixing valve This valve allows reducing setting and regulating the domestic hot water temperature at a safe level In order to adjust the mixing valve to the desire temperature create a demand for domestic hot water measuring the domestic hot water temperature will indicate the adjustment required 3 6 ELECTRICAL 3 61 Main electrical power supply The water heater electrical wiring and grounding...

Страница 8: ...INSTOMAXTM Integrated instantaneous water heater installation use and care manual Revision Sept 2013 Page 8 ...

Страница 9: ...jury and may be used as a guide in determining the safest water temperature for your applications TIME TO SCALDING VS TEMPERATURE RELATIONSHIP Temperature Time to scalding 50 C 120 F Over 5 minutes 52 C 125 F 1 1 2 to 2 minutes 54 C 130 F About 30 seconds 57 C 135 F About 10 seconds 60 C 140 F Less than 5 seconds 63 C 145 F Less than 3 seconds 66 C 150 F About 1 1 2 second 68 C 155 F About 1 secon...

Страница 10: ...heat exchanger as described in sections 4 2 and 4 3 2 Adjust temperature levels as described in section 4 4 3 Turn ON the water heater electric breaker 4 The water heater main contactor should close with an audible snap sound and all elements should turn on along with their indicator light 5 Tank temperature should gradually increase Time required for the INSTOMAX to reach the tank water temperatu...

Страница 11: ...ker before attempting any work on the water heater Visual inspection of the water heater electrical cabinet Checks for leaks at the heating elements sign of overheating of electrical components and wiring Check for t proper operation of the unit temperature control Check the thermostatic mixing valve proper operation by measuring domestic water temperature at a domestic hot water tap with a thermo...

Страница 12: ...anty is void and shall not apply if A Defects or malfunctions resulting from installation repair maintenance and or usage that are not done in conformity with the manufacturer s installation manual or B Defects or malfunctions resulting from installation maintenance or repair that are not done in accordance with regulations in force or C Defects or malfunctions resulting from improper installation...

Отзывы: