Proceed as follows to make these connections.
- Pull up and remove the top panel (1) from the boiler
- Unscrew the screws (2) and remove the cover (3) from
over the control panel
- Make the electrical connections to the boiler’s terminal
block (MO1) as shown alongside.
b
Use the cable clamp (P) to hold the mains cable in
place.
Terminals (2-3) provide a multi-functional input that can
be used to control boiler ignition from a room thermostat
for a direct heating zone.
- Connect up the outside sensor (see relevant section).
- Connecting up the room unit (not supplied)
Use a two core cable to connect the room unit to termi-
nals CL+ and CL- on the main board, taking care not to
invert polarity.
Set the relevant parameters to assign the room unit to
the corresponding circuit (see “Preparing for initial start-
up”).
- Once you have made all the necessary connections,
close the control panel, reversing the steps followed to
open it.