8
INFORMATION menu
Open the menu by pressing the left or right button. The menu also shows history and operating times.
N
The menu information below describes all possible parameters. The parameters that appear in the display
vary depending on the selections made in menus (e.g. type of heat pump) and on the connected hardware
(e.g. expansion card and defrost card).
▪
INFORMATION
▪
OPERAT.
▪
HEAT CURVE
▪
HEAT CURVE 2 (if shunt group is activated)
▪
TEMPERATURE
▪
OPERAT. TIME
▪
DEFROST
▪
LANGUAGE
8.1
Sub-menu OPERAT.
Menu selection
Meaning
Factory setting
(OFF)
The installation is fully switched off. This mode is also used to acknowledge certain
alarms.
CANCEL = starting point, no changes made.
To select OFF as operating mode, press the minus sign once to scroll down one step and
press the right arrow once.
-
AUTO
Automatic operation with both heat pump and auxiliary heater permitted. If the number
of power stages for auxiliary heating are set to zero (SERVICE -> AUX. HEATER -> MAX
STEP) only AUTO or OFF can be selected as operating mode.
-
HEAT PUMP
Operation with only compressor permitted.
N
No peak heating charging (anti-legionella function) with only
heat pump operation.
-
AUX. HEATER
Operation with only auxiliary heater permitted.
-
HOT WATER
Operation with heat pump for hot water production and auxiliary heater during peak
heating charging (anti-legionella function).
-
MANUAL TEST
Only displayed when the value for MANUAL TEST is set to 2 in the SERVICE menu. Out-
puts that control components are activated manually.
-
8.2
Sub-menu HEAT CURVE
Menu selection
Meaning
Factory setting
CURVE
Calculated supply temperature at 0°C outdoor temperature. Shown as a graphic curve.
The curve will be limited by the set values of MIN and MAX.
40°C(for under
floor heating
30°C)(range:
22°C / 56°C)
MIN
Minimum permitted supply temperature, if the temperature for heat stop has been
reached and the heat pump has stopped.
10°C(range:
10°C / 50°C)
MAX
Maximum calculated setpoint value of the supply temperature.
55°C(for under
floor heating
45°C)(range:
40°C / 85°C)
CURVE +5
Local increase or reduction of CURVE at an outdoor temperature of +5°C. Shown in the
graph for CURVE.
0°C(range: -5°C /
5°C)
Installation Guide
Domestic heat pumps
Thermia Värmepumpar
VMGFP202
47
Содержание Atria Optimum
Страница 15: ...1 Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 15 ...
Страница 72: ...Installation Guide Domestic heat pumps VMGFP202 Thermia Värmepumpar 72 ...
Страница 73: ...Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 73 ...
Страница 74: ...Installation Guide Domestic heat pumps VMGFP202 Thermia Värmepumpar 74 ...
Страница 75: ...Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 75 ...