5.2.1
System solution 1
Description
In system solution 1 the heat pump can produce both heating and hot water with the compressor and the integrated immersion heater.
Production of heating and hot water cannot occur at the same time because the exchange valve for heating/hot water is positioned
after the immersion heater.
The integrated immersion heater carries out peak heating charging (antilegionella function) in those operating modes that permit auxili-
ary heat.
For system solution 1, select the factory setting in menu SERVICE\AUX. HEATER\EXTERNAL ADDITION:
▪
EXTERNAL AUX. HEATER = 0 (Off)
▪
REV.V. HOT WATER = INT
Example system solution 1
System solution for Diplomat, Diplomat Optimum, Diplomat Optimum G2/G3, Comfort Optimum, Atria Optimum.
1
Heat pump
10
Supply line
11
Return line
12
Cold water
13
Hot water
80
Shut-off valve
83
Non-return valve
85
Air bleeding valve
86
Safety valve expansion heating system
87
Safety valve cold water 9 bar
89
Vacuum valve
91
Dirt strainer with shut off valve
96
Flexible hose
113
Expansion heating system
Installation Guide
Domestic heat pumps
Thermia Värmepumpar
VMGFP202
21
Содержание Atria Optimum
Страница 15: ...1 Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 15 ...
Страница 72: ...Installation Guide Domestic heat pumps VMGFP202 Thermia Värmepumpar 72 ...
Страница 73: ...Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 73 ...
Страница 74: ...Installation Guide Domestic heat pumps VMGFP202 Thermia Värmepumpar 74 ...
Страница 75: ...Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 75 ...