![Thermia Atria Optimum Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/thermia/atria-optimum/atria-optimum_installation-manual_1104079013.webp)
3.4.2
Foundation for outdoor unit
1. Position the outdoor unit on a stable base that can take the total weight, see
Technical data
.
2. Secure all four mounting points on a stable base, for example a cast foundation.
100 mm
~900 mm
b
c
a
7
5
4
3
6
1
8
2
Measurements
6-12 kW
1
470 mm
2
480 mm
3
672 mm
4
190 mm
5
65 mm
6
~1,200 mm
7
~720 mm
8
Ø 65 mm
Position
Description
a
Drainage hole
b
Foundation
c
Gravel
Bolt size
6-12 kW
M12 (4x)
Caution
A driptray is installed with the purpose of gathering and draining away melt water during defrosting. Connect
a hose or pipe along with a heat trace cable between the outlet of the drip tray and a drain or a free draining
piece of ground. The heat cable must be connected to the terminal provided and is necessary to prevent ice
blockage.
Caution
Check with a spirit level that the outdoor unit is installed horizontally.
Installation Guide
Domestic heat pumps
Thermia Värmepumpar
VMGFP202
13
Содержание Atria Optimum
Страница 15: ...1 Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 15 ...
Страница 72: ...Installation Guide Domestic heat pumps VMGFP202 Thermia Värmepumpar 72 ...
Страница 73: ...Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 73 ...
Страница 74: ...Installation Guide Domestic heat pumps VMGFP202 Thermia Värmepumpar 74 ...
Страница 75: ...Installation Guide Domestic heat pumps Thermia Värmepumpar VMGFP202 75 ...