cutmaster 39
Manual 0-4976
4-5
OPERATION
G. Set Operating Pressure
Place the Power Supply RUN / SET switch to the SET (down) position. Gas will flow. Adjust gas pressure to
65 psi / 4.5 bar. Gas indicator turns on.
NOTE
If gas regulator leaks, reset gas pressure to 0 psi, then reset to 65 psi / 4.5 bar.
A-07927
A
30
20
26
28
24
22
A-07933
1
2
65 psi / 4.5 bar
H. Select Current Output Level
Place RUN / SET switch to RUN (up) position. Gas flow will stop. Set the desired current output level.
A-07934
A
30
20
26
28
24
22
Содержание CUTMASTER 39
Страница 2: ......
Страница 4: ...This Page Intentionally Blank...
Страница 14: ...CutMaster 39 GENERAL INFORMATION 1 8 Manual 0 4976 This Page Intentionally Blank...
Страница 22: ...CutMaster 39 INTRODUCTION 2T 4 Manual 0 4976 This Page Intentionally Blank...
Страница 28: ...CutMaster 39 INSTALLATION 3 6 Manual 0 4976 This Page Intentionally Blank...
Страница 36: ...CutMaster 39 OPERATION 4 8 Manual 0 4976 This Page Intentionally Blank...
Страница 62: ...CutMaster 39 SERVICE 5 18 Manual 0 4976 This Page Intentionally Blank...
Страница 78: ...CutMaster 39 APPENDIX A 8 Manual 0 4976 This Page Intentionally Blank...