INSTALLATION
Power Supply Dimensions & Weight
Ventilation Clearance Requirements
15"
381 mm
12"
305 mm
24"
0.61 m
45 lb / 20.4 kg
Art # A-07924
6"
150 mm
24"
0.6 m
6"
150 mm
6"
150 mm
Art # A-07925
NOTE
Weight includes torch & leads, input power cord, and work cable with clamp.
CAUTION
Provide clearance for proper air flow through the power supply. Operation without proper air flow will inhibit
proper cooling and reduce duty cycle.
2.05 Input Wiring Specifications
CutMaster 39 Input Power Requirements
Input
Power Input Current Input
Suggested Sizes (See Notes)
Voltage
Freq.
(kVA)
(Amps)
Fuse (Amps) Wire (AWG) Wire (Canada)
(Volts)
(Hz)
1-Ph
1-Ph
1-Ph
1-Ph
1-Ph
120
50 / 60
3.6
29
35
12
12
208
50 / 60
3.5
16
20
12
12
230
50 / 60
3.4
14
20
12
12
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should
be used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
Extension Cords
Extension cords must meet National Electric Code Guidelines (and OSHA Guidelines, where applicable). Exten-
sion cords must have the same rating as the service and must have a three-pronged plug.
Содержание CUTMASTER 39
Страница 2: ......
Страница 4: ...This Page Intentionally Blank...
Страница 14: ...CutMaster 39 GENERAL INFORMATION 1 8 Manual 0 4976 This Page Intentionally Blank...
Страница 22: ...CutMaster 39 INTRODUCTION 2T 4 Manual 0 4976 This Page Intentionally Blank...
Страница 28: ...CutMaster 39 INSTALLATION 3 6 Manual 0 4976 This Page Intentionally Blank...
Страница 36: ...CutMaster 39 OPERATION 4 8 Manual 0 4976 This Page Intentionally Blank...
Страница 62: ...CutMaster 39 SERVICE 5 18 Manual 0 4976 This Page Intentionally Blank...
Страница 78: ...CutMaster 39 APPENDIX A 8 Manual 0 4976 This Page Intentionally Blank...