INSTALLATION
3.04 Gas Connections
A. Connecting Gas Supply to Unit
The connection is the same for compressed air or high pressure gas cylinders. Refer to subsection 3.4-C
if an optional air line filter is to be installed.
1. Connect the gas line to the inlet port. The illustration shows typical fittings as an example.
NOTE
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do Not
use Teflon tape as a thread sealer, as small particles of the tape may break off and block the small gas passages in
the torch.
A-07926
Min. 1/4 inch
6.4 mm
Gas Connection to Inlet Port
B. Check Air Quality
To test the quality of air, put the RUN / SET switch in the SET (down) position, place a welding filter
lens in front of the torch and turn on the gas. Any oil or moisture in the air will be visible on the lens.
Do not start an arc!
A-07927
A
30
20
26
28
24
22
C. Installing Optional Single - Stage Air Filter
An optional filter kit is recommended for improved filtering with compressed air, to keep moisture and
debris out of the torch.
1. Attach the Single - Stage Filter Hose to the Inlet Port.
2. Attach the Filter Assembly to the filter hose.
Содержание CUTMASTER 39
Страница 2: ......
Страница 4: ...This Page Intentionally Blank...
Страница 14: ...CutMaster 39 GENERAL INFORMATION 1 8 Manual 0 4976 This Page Intentionally Blank...
Страница 22: ...CutMaster 39 INTRODUCTION 2T 4 Manual 0 4976 This Page Intentionally Blank...
Страница 28: ...CutMaster 39 INSTALLATION 3 6 Manual 0 4976 This Page Intentionally Blank...
Страница 36: ...CutMaster 39 OPERATION 4 8 Manual 0 4976 This Page Intentionally Blank...
Страница 62: ...CutMaster 39 SERVICE 5 18 Manual 0 4976 This Page Intentionally Blank...
Страница 78: ...CutMaster 39 APPENDIX A 8 Manual 0 4976 This Page Intentionally Blank...