CUTMASTER 12mm
Manual 0-5077
5-15
SERVICE
P. AC LED ON, TEMP LED OFF, GAS LED
ON, Gas does not flow in SET mode using
a machine torch with remote solenoid.
Disconnect the gas solenoid SOL1 from the back of
the ATC connector.
If Gas DOES NOT flow out of SOL1 when the unit is
in SET mode :
1. Defective gas solenoid (SOL1)
a) Measure voltage on Main PCB between J5-1 to
J5-3 for 12 VDC. If voltage is present, change
SOL 1
2. Defective Logic PCB
a) Measure on Main PCB between J2-12 to test
point GND1 for 12VDC. If voltage is present,
replace Main PCB.
3. Defective Main PCB
a) Replace Main PCB
If gas DOES flow out of SOL1 when the unit is in SET
mode, reconnect SOL1 to the ATC connector.
4. Defective torch solenoid.
a) Measure the coil terminals of the torch mount-
ed gas solenoid SOL2 for 24VAC. If present,
replace SOL2.
5. Defective Main PCB
a) Measure on Main PCB between J2-20 to GND1
for less than 2VDC.
If voltage is 12VDC replace Main PCB
b) Measure on Main PCB between J2-11 to GND1
for less than 2VDC. If voltage is less than
2VDC replace Main PCB
6. Defective Logic PCB
a) Measure on Main PCB between J2-11 to GND1
for less than 2VDC. If voltage is 12VDC, re-
place Logic PCB.
Q. Cannot adjust gas pressure in the SET
mode
1. Inlet gas pressure is too low
a) Increase inlet gas pressure to 95-120 psi
2. Faulty regulator
a) Replace Regulator
5.09 Pilot Arc Problems
A. AC LED ON, TEMP LED OFF, GAS LED
ON. Nothing happens when torch switch
or remote switch is closed (Or CNC START
signal is active) No gas flow, DC LED
OFF.
1. Problem in the torch and leads switch circuit (or
remote pendant or CNC signal missing
a) For hand torches, check continuity of torch
switch circuit at ATC pins 3 & 4.
Negative / Plasma Lead
4 Torch Switch
3 Torch Switch
2 PIP
1 PIP
Pilot Lead
Art # A-08124
b) For machine torches using a remote pendant,
check continuity of Pendant switch circuit
c) For CNC input see section "5.07 H Tip Missing
Fault"
2. Defective Logic PCB
a) Jumper on Main PCB between J2-16 and test
point GND1. If gas does not flow, replace
Logic PCB
b) With Torch Switch closed, measure voltage
on Main PCB between test points GND1 to
I_DMD1 for 1.4VDC. Replace Logic PCB if
voltage is not present.
3. Defective Main PCB 1
a) With Torch Switch closed, measure voltage
on Main PCB between test points GND1 to
I_DMD1 for 1.4 VDC. Replace Main PCB 1 if
voltage is present.
Содержание A-08950
Страница 4: ...This Page Intentionally Blank ...
Страница 8: ...This Page Intentionally Blank ...
Страница 16: ...CUTMASTER 12mm GENERAL INFORMATION 1 8 Manual 0 5077 This Page Intentionally Blank ...
Страница 24: ...CUTMASTER 12mm INTRODUCTION 2T 4 Manual 0 5077 This Page Intentionally Blank ...
Страница 34: ...CUTMASTER 12mm OPERATION 4 4 Manual 0 5077 This Page Intentionally Blank ...
Страница 48: ...CUTMASTER 12mm OPERATION 4T 14 Manual 0 5077 This Page Intentionally Blank ...
Страница 69: ...CUTMASTER 12mm Manual 0 5077 5 21 SERVICE This Page Intentionally Blank ...
Страница 73: ...CUTMASTER 12mm Manual 0 5077 5 25 SERVICE This Page Intentionally Blank ...
Страница 77: ...CUTMASTER 12mm Manual 0 5077 5 29 SERVICE This Page Intentionally Blank ...
Страница 78: ...CUTMASTER 12mm SERVICE 5 30 Manual 0 5077 This Page Intentionally Blank ...
Страница 89: ...CUTMASTER 12mm Manual 0 5077 6 9 PARTS LIST A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Страница 98: ...CUTMASTER 12mm PARTS REPLACEMENT 7 8 Manual 0 5077 This Page Intentionally Blank ...