CUTMASTER 12mm
Manual 0-5077
5-13
SERVICE
H. PARTS-IN-PLACE (PIP) FAULT. The
FAULT Indicator and 70 PSI LED is
flashing.
1. Shield Cup loose
a) Hand tighten the shield cup to close the PIP
switch
2. Torch not properly connected to power supply
a) Insure torch ATC is securely fastened to unit.
3. Problem with torch and leads PIP circuit
a) Check continuity of torch PIP circuit at ATC
pins 1 & 2.
Negative / Plasma Lead
4 Torch Switch
3 Torch Switch
2 PIP
1 PIP
Pilot Lead
Art # A-08124
4. Defective Logic PCB
a) Measure the voltage on Main PCB between
J2-17 to test point GND1 for 12VDC. If the
voltage is less than 2VDC, replace Logic PCB
5. Defective Main PCB
a) Replace Main PCB
I. START ERROR FAULT. The FAULT
Indicator and 75 PSI LED is flashing.
1. Start signal is active when SW1 is turned to ON
position.
a) Start can be active for one of the following:
•
Hand torch switch held closed
•
Hand pendant switch held closed
•
CNC START signal is active low
Release the START signal source
2. Problem in the torch and leads switch circuit
a) Check continuity of torch switch circuit at ATC
pins 3 & 4. See previous illustration.
3. Short in CNC cable
a) Check continuity
4. Defective Logic PCB (PCB 3)
a) Measure voltage at Main PCB between J2-16
to test point GND1 for 12VDC. If voltage is
present, replace Logic PCB
5. Defective Main PCB
a) Replace Main PCB.
J. TIP MISSING FAULT. The FAULT Indicator
and 80 PSI LED is flashing. Gas solenoid
cycles ON and OFF.
1. Torch Shield Cup is loose.
a) Tighten shield cup by hand. Do not over
tighten.
2. Torch tip, electrode, or starter cartridge missing.
a) Turn OFF power supply. Replace missing
part(s).
3. Starter Cartridge is stuck.
a) Turn OFF power supply. Bleed down the sys-
tem. Remove the shield cup, tip,start cartridge
and electrode. Check the lower end unit of the
start cartridge for free movement. Replace the
cartridge if the lower end unit does not move
freely.
Art # A-08064_AC
Spring-Loaded
Lower End Fitting
Full Compression
Spring-Loaded
Lower End Fitting at Reset /
Full Extension
4. Open conductor in torch leads
a) Check continuity
5. Defective Main PCB
b) Measure voltage at Main PCB between J2-2
to test point GND1 for 12VDC. If voltage is
present, replace Main PCB
6. Defective Logic PCB
a) Replace Logic PCB
Содержание A-08950
Страница 4: ...This Page Intentionally Blank ...
Страница 8: ...This Page Intentionally Blank ...
Страница 16: ...CUTMASTER 12mm GENERAL INFORMATION 1 8 Manual 0 5077 This Page Intentionally Blank ...
Страница 24: ...CUTMASTER 12mm INTRODUCTION 2T 4 Manual 0 5077 This Page Intentionally Blank ...
Страница 34: ...CUTMASTER 12mm OPERATION 4 4 Manual 0 5077 This Page Intentionally Blank ...
Страница 48: ...CUTMASTER 12mm OPERATION 4T 14 Manual 0 5077 This Page Intentionally Blank ...
Страница 69: ...CUTMASTER 12mm Manual 0 5077 5 21 SERVICE This Page Intentionally Blank ...
Страница 73: ...CUTMASTER 12mm Manual 0 5077 5 25 SERVICE This Page Intentionally Blank ...
Страница 77: ...CUTMASTER 12mm Manual 0 5077 5 29 SERVICE This Page Intentionally Blank ...
Страница 78: ...CUTMASTER 12mm SERVICE 5 30 Manual 0 5077 This Page Intentionally Blank ...
Страница 89: ...CUTMASTER 12mm Manual 0 5077 6 9 PARTS LIST A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Страница 98: ...CUTMASTER 12mm PARTS REPLACEMENT 7 8 Manual 0 5077 This Page Intentionally Blank ...
Страница 107: ...This Page Intentionally Blank ...