CUTMASTER 12mm
SERVICE
5-18
Manual 0-5077
5.12 Test Procedures
A. Main Contactor (W1) Test
1. Check continuity between:
L1 to T1
L2 to T2
L3 to T3
L4 to T4
The contacts should be open – no continuity.
L4
L3
L2
L1
T4
T3
T2
T1
Actuator Arm
Cover Screws
Art # A-08157_AB
Input
Side
CutMaster 52 & 82
W1 contactor wired for 1PH
Main Contactor
Jumpers
Actuator Button
2. Retest continuity between terminals while engag-
ing the contacts manually. This can be done by
pushing down on the recessed actuator button on
the top of W1 or pushing down on the actuator
arm on the side of W1.
L1 to T1
L2 to T2
L3 to T3
L4 to T4
The contacts should be closed – Continuity
3. Visually check W1 contact points. To take the
cover OFF, remove the two cover screws shown
in the previous illustration. Replace if contacts
are stuck together or show excessive arcing
B. Input Diode Module Test
1. Using an ohmmeter perform the tests in the
chart
Input Diode Module
Meter (+)
Meter (-)
Indication
AC1
MTH 2
Forward Bias
AC2
MTH 2
Forward Bias
AC3
MTH 2
Forward Bias
MTH 2
AC1
Reverse Bias
MTH 2
AC2
Reverse Bias
MTH 2
AC3
Reverse Bias
MTH 5
AC1
Forward Bias
MTH 5
AC2
Forward Bias
MTH 5
AC3
Forward Bias
AC1
MTH 5
Reverse Bias
AC2
MTH 5
Reverse Bias
AC3
MTH 5
Reverse Bias
2
.
If the test reveals a failed component, replace
Main PCB and perform main contactor test – Sec-
tion 5.11-A
C. Input Capacitor PCB Test
1. Using an ohmmeter check continuity between the
following points:
Input Capacitors
Meter +
Meter -
Indication
MTH 2
MTH 4
Charging
MTH 4
MTH 5
Open
MTH 6
MTH 5
Charging
Most meters will show a charging action. Initially a
low resistance will be shown and then the resistance
will start to increase. If the meter probes are reversed
the reading will decrease to zero, then start charging
in the opposite polarity.
2. If a short is found replace Capacitor PCB assem-
bly.
3. Check continuity between the following points
Input relays
Indication
MTH 2
MTH 6
Open
MTH 4
MTH 6
Open
MTH 4
MTH 5
Open
4. If a short is found, replace Capacitor PCB assem-
bly.
Содержание A-08950
Страница 4: ...This Page Intentionally Blank ...
Страница 8: ...This Page Intentionally Blank ...
Страница 16: ...CUTMASTER 12mm GENERAL INFORMATION 1 8 Manual 0 5077 This Page Intentionally Blank ...
Страница 24: ...CUTMASTER 12mm INTRODUCTION 2T 4 Manual 0 5077 This Page Intentionally Blank ...
Страница 34: ...CUTMASTER 12mm OPERATION 4 4 Manual 0 5077 This Page Intentionally Blank ...
Страница 48: ...CUTMASTER 12mm OPERATION 4T 14 Manual 0 5077 This Page Intentionally Blank ...
Страница 69: ...CUTMASTER 12mm Manual 0 5077 5 21 SERVICE This Page Intentionally Blank ...
Страница 73: ...CUTMASTER 12mm Manual 0 5077 5 25 SERVICE This Page Intentionally Blank ...
Страница 77: ...CUTMASTER 12mm Manual 0 5077 5 29 SERVICE This Page Intentionally Blank ...
Страница 78: ...CUTMASTER 12mm SERVICE 5 30 Manual 0 5077 This Page Intentionally Blank ...
Страница 89: ...CUTMASTER 12mm Manual 0 5077 6 9 PARTS LIST A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Страница 98: ...CUTMASTER 12mm PARTS REPLACEMENT 7 8 Manual 0 5077 This Page Intentionally Blank ...
Страница 107: ...This Page Intentionally Blank ...