![Thermal Arc ULTRA FLEX 350 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/thermal-arc/ultra-flex-350/ultra-flex-350_owners-manual_1103199031.webp)
There are two separate safes, one for single
phase operation and one for three phase opera-
tion. These safes are independent of each other,
and are accessed automatically when the ma-
chine is powered up in either the single or three
phase mode. Any changes to one will not affect
the other.
OPTION
NUMBER
OPTION
FACTORY DEFAULT DISPLAY
FORMAT
1 PHASE 3 PHASE
0
RESET THE SYSTEM.
This option resets all SAFE parameters to their factory default
settings. “nO” means do not reset the system to factory default
while “rES” means reset the system to factory default settings.
Only the single phase settings will be reset if the machine is
hooked up to single phase power. Likewise, only the three phase
settings will be reset when hooked to three phase power.
NOTE: THE SAVE BUTTON MUST BE DEPRESSED WHEN
EXITING THE SAFE IN ORDER FOR THE RESET TO OCCUR.
nO
nO
0XXX
1
WIRE SHARP VOLTAGE SETTING.
This is the voltage that will be present on the wire following a
GMAW or Pulsed GMAW weld. This feature “sharpens” the wire
by burning off the ball of filler metal that often forms on the end
of the wire following a GMAW weld. The voltage can be set to
any value between 0 and 20 volts in increments of 1 volt.
10
10
1_XX
2
WIRE SHARP TIME.
Wire sharp time is the length of time following a GMAW or Pulsed
GMAW weld that the wire sharp voltage will remain on the filler
wire. This variable time is adjustable between 0 and 1 second in
increments of 0.01 seconds. Longer times will give more of a
burnback effect.
.25
.25
2XXX
3
MAXIMUM SELECTABLE AMPERAGE.
Maximum selectable amperage is the largest amperage value
that the user is capable of setting in SMAW, Lift GTAW, or GTAW
local mode. This feature is effective when the user would like to
insure that the amperage is never set above a particular
amperage level. The range of values permitted is 5-275 amps
(single phase) and 5-375 amps (three phase). The maximum
selectable amperage is never permitted to be set less than the
minimum selectable amperage.
275
375
3XXX
4
MINIMUM SELECTABLE AMPERAGE.
Minimum selectable amperage is the lowest amperage value that
the user is capable of setting in SMAW, Lift GTAW, or GTAW
local mode. This feature is effective when the user would like to
insure that the amperage is never set below a particular
amperage level. The range of values permitted is 5-275 amps
(single phase) and 5-375 amps (three phase). The minimum
selectable amperage is never permitted to be set greater than
the maximum selectable amperage.
5
5
4XXX
5
MAXIMUM SELECTABLE VOLTAGE.
This voltage is the largest value that the user is capable of setting
in GMAW local welding mode. Voltages above this value can not
be entered by the user in local mode. This voltage value can be
exceeded in remote by using a feeder with voltage setting
capability. The range of values permitted is 10-31 volts (single
phase) and 10-35 volts (three phase). The maximum selectable
voltage is never permitted to be set less than the minimum
selectable voltage.
31.0
35.0
5XX.X
430429-465
OPERATION
February 28, 2000
5-9
Содержание ULTRA FLEX 350
Страница 4: ...This page intentionally left blank 430429 465 INTRODUCTION 1 2 February 28 2000...
Страница 15: ...Figure 3 2 Volt Ampere Curves 430429 465 DESCRIPTION OF EQUIPMENT February 28 2000 3 3...
Страница 22: ...This page intentionally left blank 430429 465 INSTALLATION 4 4 February 28 2000...
Страница 34: ...This page intentionally left blank 430429 465 OPERATION 5 12 February 28 2000...
Страница 36: ...This page intentionally left blank 430429 465 MAINTENANCE 6 2 February 28 2000...
Страница 40: ...This page intentionally left blank 430429 465 TROUBLESHOOTING 7 4 February 28 2000...
Страница 42: ...Figure 8 1 Ultra Flex Welder Assembly 430429 465 PARTS LIST 8 2 February 28 2000...
Страница 44: ...Figure 8 2 430429 465 PARTS LIST 8 4 February 28 2000...
Страница 46: ...This page intentionally left blank 430429 465 PARTS LIST 8 6 February 28 2000...
Страница 47: ......
Страница 48: ......
Страница 49: ......