Notice NOT 034
THERMAL ARC 180 AC/DC
Rev : 00
Date : 03/12/02
USING
USER’S MANUAL
Page
2
0/36
Y
Up slope time
Press the setting key
F8
, adjust the up-slope time with the potentiometer
F9
.
When the potentiometer is at the minimum, the up-slope time is 0s, and at the maximum, the up-slope
time is 10s.
The value can be read on the display
F5
(The indicator
F18
or
F19
goes out).
The pre-adjusted value is 1.0s.
Release the key when your setting is finished.
Z
Down-slope time
Adjust the down-slope time between 0s to 16s with the potentiometer
F10
.
[
Post-gas :
Press the setting key
F11
, adjust the post-gas time with the potentiometer
F9
.
When the potentiometer is at the minimum, the pre-gas time is 3s, and at the maximum, the pre-gas
time is 25s.
The value can be read on the display
F5
(The indicator
F18
or
F19
goes out).
The pre-adjusted value is 5.0s.
Release the key when your setting is finished.
\
Welding current :
Set the welding current from 3A to maximum value with potentiometer
F9
.
The value can be read on the display
F5
and indicator
F18
illuminates.
12.3.
WELDING
Select tungsten electrode
Place on the torch a tungsten electrode thoriated 2% or 4%, or even better, electrode DLZ (Itrium
Lanthane Zirconium) or lanthane, not so radioactive.
Grid electrode’s head at 60° or 90°.
See adviced electrode’s diameter adapted to welding current.
Electrode’s diameter
mm
1
1.6
2.0
2.4
3.0
4.0
Welding DC current
A
<75
50 - 120
90 - 190 130 - 250 170 - 300 250 - 400
H.F ignition
Place the tungsten electrode a few mm away from the workpiece.
Press the trigger on.
After the selected pre-gas time, the arc strikes. The high frequency stops.
The welding current increases during the up-slope time between the value of initial current and the
value of welding current chosen.
The value of the initial current (
I
d
) is pre-adjusted at 50% of the value of welding current chosen but it
is possible to adjust (see
chapter 16
).
At the end of the weld, the arc fades away during the down-slope time and the welding current
reduces from the welding current chosen to the final current.
The final current (
I
f
) is pre-adjusted to 3A but it is possible to adjust it (see
chapter 16
).
The arc goes out. The gas flows according to the post-gas time to ensure the protection of the
tungsten as well as of the weld pool.
Содержание 180 AC
Страница 1: ...THERMAL ARC 180 AC DC USER S MANUAL ...
Страница 34: ...21 WIRING DIAGRAM ...