Notice NOT 034
THERMAL ARC 180 AC/DC
Rev : 00
Date : 03/12/02
USING
USER’S MANUAL
Page
2
5/36
50% of balance means that the 2 alternating positive and negative are equal.
Balance can be adjusted from 20% to 60% (cleaning).
In order to maintain a sharp tungsten it is better to use a shorter cleaning time
The balance is pre-adjusted to 40% (cleaning 40% - penetration 60%), which is a good solution
between the 2 modes and allow aluminium welding in almost all the cases.
Z
Select tungsten electrode
Place a tungsten electrode pure or DLZ (Itrium Lanthane Zirconium) or lanthane, without radiation.
For low current, use the smallest diameter possible.
For very low current (3A to 15A), use only grinded tungsten electrode
Electrode’s diameter
mm
1
1.6
2.0
2.4
3.0
4.0
5.0
Welding AC current
A
<50
40 - 80
60 - 110
70 - 140
90 - 180
160 - 240 230 - 340
[
Welding
For the adjustment of other parameters and for welding, see instructions given in
chapter 12 : DC
Current TIG welding
15.
TIG WELDING IN PULSE AC CURRENT
The selection of « TIG in AC current » welding mode is made in 4 stages :
X
Select TIG welding mode
Press the setting key
F14
to choose « TIG welding mode », the indicator
F24
illuminates.
To adjust the parameters, see instructions given in
chapter 12 : DC Current TIG welding
Y
Select « pulse DC current» welding mode
Press the setting key
F15
one time to choose « pulse DC current welding mode », the indicator
F27
illuminates (indicator
F26
OFF).
To adjust the parameters, see instructions given in
chapter 13 : TIG welding in pulse DC current
Z
Select « AC current » welding mode
Press the setting key
F15
one time to choose « pulse current welding mode », the indicator
F26
illuminates (indicator
F27
dies out).
To adjust the parameters, see instructions given in
chapter 14 : AC current TIG welding