1 Intended Application

The intended application for the Vehere is as a pool & 

spa area humidity sensing controller applied either as a 

free-standing device directly in the pool area or operated 

remotely to provide dehumidified air to the pool or spa area 

using optional ducting and remotely mounting the humidity 

controller. The Vehere high efficiency dehumidifier utilizes 

refrigeration to cool an incoming air stream below its 

dewpoint as it passes through an evaporator coil. This  

cooling results in the removal of moisture (latent heat). The 

cooled and dried air is used to pre-cool the incoming air 

stream resulting in up to a 200 percent increase in overall 

efficiency.

2 Specifications

Model:

 HI-E Dry Vehere 

Electrical:

 110-120 VAC, 12.0 Amps, grounded 

 

   (7’ power cord included)

Compressor LRA:

 63 Amps

Capacity:

 192 pints/day @ 80°F, 60% RH

Energy Factor:

 2.79 L/kWh

Air Flow:

 540 CFM without external ducting

 

 510 CFM @ .15 IWG external static

Refrigerant Charge:

 2 lbs., 8 oz. R410a

Optional Duct Connections: 

12” round inlet & outlet

Size (w/o duct collars):

  36.5” Long x 19” Wide x 40” High

Weight:

 180 lbs.

Controller Accuracy:

 +/- 5% RH @ 72°F

Capacities

The Vehere is designed to control humidity for indoor pool 

(spa, hot tub) areas. It consists of a controller, dehumidifying 

cooling system, filter, fan and delivers the following 

dehumidification capacities: 

Air Temp/Relative Humidity 

Lbs./Hour 

Lbs./Day

82°F/60%RH* 

8.67 

208

80°F/60%RH 

8.32 

200

 

Air Temp/Relative Humidity 

Pints/Hour 

Pints/Day

82°F/60%RH* 

8.33 

200

80°F/60%RH 

8.00 

192

Air Temp/Relative Humidity 

BTUs/Hour  

KWH/Day 

 

 (derived)

82°F/60%RH* 

13,668 

35.71

80°F/60%RH 

13,299 

34.56   

*ASHRAE Recommended Conditions

Read these installation, operation and service instructions 

carefully before installing and using this unit. Proper 

adherence to these instructions is essential to obtain 

maximum benefit from your Vehere pool & spa humidity 

controller.

• If used near a pool or spa, be certain there is NO chance 

the unit could roll into the water or be splashed and that 

it is plugged into a GROUND FAULT INTERRUPTER.

• DO NOT use the Vehere as a bench or table.
• Avoid discharging the exhaust directly at people or pets.

Table of Contents

Precautions..............................................................................1

1.  Intended Application for Vehere

 ....................................1

2.  Specifications & Capacities

 ............................................1

 

2.1 Vehere Diagram .........................................................2

3. Installation

 .......................................................................2

 

3.1 Location .....................................................................2

 

   3.1A Improper Installation .........................................2

 

   3.1B In humid area, no ducting ................................3

 

   3.1C In humid area, duct inlet and/or outlet ...........4

 

   3.1D In remote area, duct inlet & outlet ..................4

 

3.2 Mounting the Humidity Sensor/Controller ..............5

 

3.3 Electrical Requirements ............................................5

 

3.4 Condensate Removal ................................................5

 

3.5 Ducting .......................................................................5

 

   3.5A Ducting kit .........................................................5

 

   3.5B Ducting for Dehumidification ...........................6

4.   Operation

 .........................................................................6

 

4.1 Humidity Control ........................................................6

 

4.2 Humidity Control Adjustment ....................................6

 

4.3 Fan Switch .................................................................6

 

4.4 Automatic Defrost Control ........................................6

 

4.5 Automatic Low Pressure Control ..............................6

5. Ventilation

 ........................................................................7

 

5.1 Ventilation Recommendations .................................7

6. Maintenance

 ....................................................................7

 

6.1 Air Filter ......................................................................7

7. Service

 ..............................................................................7

 

7.1 Technical Description ................................................7

 

7.2 Troubleshooting .........................................................7

 

7.3 Refrigerant Charging .................................................8

 

7.4 Blower Replacement .................................................8

 

7.5 Relay ...........................................................................8

8.  Vehere Accessories

 .........................................................8

9.  Vehere Electrical Wiring Diagram

 ..................................9

10. Service Parts

 ..................................................................10

11. Warranty

 .........................................................................11

Содержание HI-E Dry Vehere

Страница 1: ...dehumidifier resulting in a compact refrigeration system requiring less electric consumption This ensures the use of a standard 20 Amp electrical outlet and LOW OPERATING COSTS HI Capacity Vehere s pa...

Страница 2: ...60 RH 8 32 200 Air Temp Relative Humidity Pints Hour Pints Day 82 F 60 RH 8 33 200 80 F 60 RH 8 00 192 Air Temp Relative Humidity BTUs Hour KWH Day derived 82 F 60 RH 13 668 35 71 80 F 60 RH 13 299 34...

Страница 3: ...talled in a variety of locations to meet the owner s needs other considerations include 1 Providing access to a 115 VAC power outlet 7 power cord is provided 2 Locating near a floor or other suitable...

Страница 4: ...idification can be improved by adding an inlet and or outlet duct to circulate and destratify stagnant areas Add inlet or outlet ducting to create flow across the area s greatest length For areas with...

Страница 5: ...this manual Replace plastic housing 3 3 Electrical Requirements The Vehere can be plugged into any grounded 20 Amp circuit At 80 F 60 RH it draws 12 Amps A dedicated 20 Amp circuit is recommended 3 4...

Страница 6: ...it moving the controller toward Low to lower the humidity and toward High to increase the level of humidity in your pool or spa area Approximate Humidity Levels Per Setting Low 35 to 45 Relative Humid...

Страница 7: ...by giving up its heat to the air it discharges from the unit The refrigerant liquid then passes through two capillary tubes which cause the refrigerant pressure and temperature to drop It next enters...

Страница 8: ...4 Blower Replacement The blower has a PSC motor internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug the power cord 2 Remove the cabinet front 3 If an out...

Страница 9: ...9 www thermastor com sales thermastor com Toll Free 1 800 533 7533 9 Vehere Electrical Wiring Figure 12 Vehere wiring diagram...

Страница 10: ...ntrol Low Pressure 9 4025278 1 Cord Wire Harness 10 4021470 1 Defrost Thermostat 4021648 1 Defrost Thermostat Mounting Clip 11 4021799 2 Filter Air 2 X 16 X 16 Grainger P N 6B958 12 4025087 1 Filter D...

Страница 11: ...care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any HI E Dry Ve...

Отзывы: