background image

9

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

9 Vehere Electrical Wiring

Figure 12: Vehere wiring diagram.

Содержание HI-E Dry Vehere

Страница 1: ...dehumidifier resulting in a compact refrigeration system requiring less electric consumption This ensures the use of a standard 20 Amp electrical outlet and LOW OPERATING COSTS HI Capacity Vehere s pa...

Страница 2: ...60 RH 8 32 200 Air Temp Relative Humidity Pints Hour Pints Day 82 F 60 RH 8 33 200 80 F 60 RH 8 00 192 Air Temp Relative Humidity BTUs Hour KWH Day derived 82 F 60 RH 13 668 35 71 80 F 60 RH 13 299 34...

Страница 3: ...talled in a variety of locations to meet the owner s needs other considerations include 1 Providing access to a 115 VAC power outlet 7 power cord is provided 2 Locating near a floor or other suitable...

Страница 4: ...idification can be improved by adding an inlet and or outlet duct to circulate and destratify stagnant areas Add inlet or outlet ducting to create flow across the area s greatest length For areas with...

Страница 5: ...this manual Replace plastic housing 3 3 Electrical Requirements The Vehere can be plugged into any grounded 20 Amp circuit At 80 F 60 RH it draws 12 Amps A dedicated 20 Amp circuit is recommended 3 4...

Страница 6: ...it moving the controller toward Low to lower the humidity and toward High to increase the level of humidity in your pool or spa area Approximate Humidity Levels Per Setting Low 35 to 45 Relative Humid...

Страница 7: ...by giving up its heat to the air it discharges from the unit The refrigerant liquid then passes through two capillary tubes which cause the refrigerant pressure and temperature to drop It next enters...

Страница 8: ...4 Blower Replacement The blower has a PSC motor internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug the power cord 2 Remove the cabinet front 3 If an out...

Страница 9: ...9 www thermastor com sales thermastor com Toll Free 1 800 533 7533 9 Vehere Electrical Wiring Figure 12 Vehere wiring diagram...

Страница 10: ...ntrol Low Pressure 9 4025278 1 Cord Wire Harness 10 4021470 1 Defrost Thermostat 4021648 1 Defrost Thermostat Mounting Clip 11 4021799 2 Filter Air 2 X 16 X 16 Grainger P N 6B958 12 4025087 1 Filter D...

Страница 11: ...care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any HI E Dry Ve...