background image

11

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

HI-E DRY Vehere Dehumidifier Limited Warranty

Warrantor:

Therma-Stor LLC
4201 Lien Rd
Madison, WI 53704
Telephone: 1-800-533-7533

WARRANTY:

 This warranty covers the HI-E Dry Vehere. 

Year One

 - 100% parts and labor (all components)

Year(s) Two through Five

 - The condenser, evaporator and compressor of the HI-E Dry Vehere will 

operate free of any defects in material or will repair or replace the defective part(s).
If a defect in materials or workmanship occurs within the warranty period, Therma-Stor LLC will repair 

or replace the defect.

USER RESPONSIBILITIES

: Warranty service must be performed by a servicer authorized by Therma-

Stor LLC. To obtain warranty service you must obtain a return material authorization (RMA). To obtain 

an RMA you must present proof of purchase or (lease), by use of a warranty card, original sales 

receipt or other reasonable and  reliable means.
To obtain an RMA call Therma-Stor LLC at the above number and ask for the Therma-Stor LLC 

Service Department, which will then issue an RMA# and arrange for, at our option, either repair or 

replacement. 

FREIGHT:

 Freight to and from the servicer is the responsibility of the end-user. The end-user is 

responsible for normal care and proper return packaging. 

LIMITATIONS AND EXCLUSIONS:

 This warranty does not cover any defect, malfunction, etc. 

resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, 

unauthorized or improper repair or installation, accident, acts of nature or any other cause beyond 

Therma-Stor LLC’s reasonable control.
If any HI-E Dry Vehere part is repaired or replaced, the new part shall be warranted for the balance 

of original warranty (but all warranty periods will be extended by the period of time, if any, that the 

Vehere is out of service while awaiting covered warranty service).
Warranty service will be performed during normal working hours.
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE HI-E DRY Vehere OR ANY 

PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-

STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR  BASED 

ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC, IN CONNECTION WITH THE 

SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY HI-E DRY Vehere OR PART THEREOF 

BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES 

INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END USER SHOULD TAKE PRECAUTIONS 

AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL 

PROPERTY. 
Some states do not allow limitations on how long an implied warranty lasts, and some do not 

allow the exclusion or limitation of incidental or consequential damages, so one or both of these 

limitations may not apply to you.

LEGAL RIGHTS:

 This warranty gives you  specific legal rights, and you may also have other rights 

which vary from state to state.

Содержание HI-E Dry Vehere

Страница 1: ...dehumidifier resulting in a compact refrigeration system requiring less electric consumption This ensures the use of a standard 20 Amp electrical outlet and LOW OPERATING COSTS HI Capacity Vehere s pa...

Страница 2: ...60 RH 8 32 200 Air Temp Relative Humidity Pints Hour Pints Day 82 F 60 RH 8 33 200 80 F 60 RH 8 00 192 Air Temp Relative Humidity BTUs Hour KWH Day derived 82 F 60 RH 13 668 35 71 80 F 60 RH 13 299 34...

Страница 3: ...talled in a variety of locations to meet the owner s needs other considerations include 1 Providing access to a 115 VAC power outlet 7 power cord is provided 2 Locating near a floor or other suitable...

Страница 4: ...idification can be improved by adding an inlet and or outlet duct to circulate and destratify stagnant areas Add inlet or outlet ducting to create flow across the area s greatest length For areas with...

Страница 5: ...this manual Replace plastic housing 3 3 Electrical Requirements The Vehere can be plugged into any grounded 20 Amp circuit At 80 F 60 RH it draws 12 Amps A dedicated 20 Amp circuit is recommended 3 4...

Страница 6: ...it moving the controller toward Low to lower the humidity and toward High to increase the level of humidity in your pool or spa area Approximate Humidity Levels Per Setting Low 35 to 45 Relative Humid...

Страница 7: ...by giving up its heat to the air it discharges from the unit The refrigerant liquid then passes through two capillary tubes which cause the refrigerant pressure and temperature to drop It next enters...

Страница 8: ...4 Blower Replacement The blower has a PSC motor internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug the power cord 2 Remove the cabinet front 3 If an out...

Страница 9: ...9 www thermastor com sales thermastor com Toll Free 1 800 533 7533 9 Vehere Electrical Wiring Figure 12 Vehere wiring diagram...

Страница 10: ...ntrol Low Pressure 9 4025278 1 Cord Wire Harness 10 4021470 1 Defrost Thermostat 4021648 1 Defrost Thermostat Mounting Clip 11 4021799 2 Filter Air 2 X 16 X 16 Grainger P N 6B958 12 4025087 1 Filter D...

Страница 11: ...care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any HI E Dry Ve...

Отзывы: