background image

5

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

Controller

If the Vehere is to be located in a remote location outside 

the pool or spa area, mounting of the humidity sensor in the 

space to be conditioned is necessary. If the humidity sensor 

is not located in the conditioned space, the Vehere will not 

operate properly.

IMPORTANT: Locate the humidity element on an inside wall, free 
from drafts, out of direct sunlight, and where the element is not 
exposed to excessive vibration. Be careful not to drop the unit. 
Mount the wall mount element at a height of 4 to 6 feet (1.2 to 
1.8 m) above the floor.

To mount the HI-E DRY Vehere dehumidistat on a wall for 

remote application, first remove the cover from the controller 

by lifting the side of the controller cover over the catch tabs 

on both sides. The cover comes off easily.

Hold the unit to the surface you would like to mount it on. You 

will need to mark the locations for two screw holes and one 

square knockout to accommodate wires and the devices wire 

guard. The wire-guard tabs fit inside the wall.  (See Fig. 6, 7) 

Once marked, drill a 1/8” hole for each mounting screw 

location and tap the provided anchor mount into the hole. 

Use the provided screws to then mount the humidity  

control to the wall. Route the wiring through the hole you 

have created and connect wires according to the directions 

found in this manual. Replace plastic housing.

3.3 Electrical Requirements

The Vehere can be plugged into any grounded 20 Amp circuit. 

At 80°F, 60% RH, it draws 12 Amps. A dedicated 20 Amp 

circuit is recommended.

3.4 Condensate Removal

Condensate drains by gravity via the clear hose extending 

from the unit. Route the 4’ drain hose to a floor drain. Use 

care to keep the hose as flat to the floor as possible. Keep 

the hose away from walk ways if possible. Excessive humps 

or kinks will prevent proper drainage. If the Vehere is located 

too far from a floor drain for the attached hose to reach, 

inexpensive 1/2” PVC pipe can be used to extend it. It is 

commonly available in 10’ lengths from building supply, 

plumbing and hardware stores. It will slide tightly inside the 

end of the drain hose. If more than one length of pipe is 

required, they can be joined with a short piece cut from the 

end of the drain hose.

3.5 Ducting

3.5A Ducting kit

The factory installation kit includes two twelve-inch collars 

to allow ducting to be attached to the inlet and outlet of 

the Vehere. The 12” collar with three tabs can be attached 

via the holes provided in the front of the unit, and the 12” 

flanged collar can be affixed to the top opening. S (See Fig. 8)

3.5B Ducting for Dehumidification

Ducting the Vehere as mentioned requires consideration of 

Figure 6:  Mark mounting 

holes as indicated by arrows.

Figure 7: Control 

connection wires.

Figure 8: Tabbed duct collar is installed around the exhaust 

outlet. The flanged duct collar is installed around the intake 

opening.

Tabbed duct collar

Flanged duct 

collar

Содержание HI-E Dry Vehere

Страница 1: ...dehumidifier resulting in a compact refrigeration system requiring less electric consumption This ensures the use of a standard 20 Amp electrical outlet and LOW OPERATING COSTS HI Capacity Vehere s pa...

Страница 2: ...60 RH 8 32 200 Air Temp Relative Humidity Pints Hour Pints Day 82 F 60 RH 8 33 200 80 F 60 RH 8 00 192 Air Temp Relative Humidity BTUs Hour KWH Day derived 82 F 60 RH 13 668 35 71 80 F 60 RH 13 299 34...

Страница 3: ...talled in a variety of locations to meet the owner s needs other considerations include 1 Providing access to a 115 VAC power outlet 7 power cord is provided 2 Locating near a floor or other suitable...

Страница 4: ...idification can be improved by adding an inlet and or outlet duct to circulate and destratify stagnant areas Add inlet or outlet ducting to create flow across the area s greatest length For areas with...

Страница 5: ...this manual Replace plastic housing 3 3 Electrical Requirements The Vehere can be plugged into any grounded 20 Amp circuit At 80 F 60 RH it draws 12 Amps A dedicated 20 Amp circuit is recommended 3 4...

Страница 6: ...it moving the controller toward Low to lower the humidity and toward High to increase the level of humidity in your pool or spa area Approximate Humidity Levels Per Setting Low 35 to 45 Relative Humid...

Страница 7: ...by giving up its heat to the air it discharges from the unit The refrigerant liquid then passes through two capillary tubes which cause the refrigerant pressure and temperature to drop It next enters...

Страница 8: ...4 Blower Replacement The blower has a PSC motor internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug the power cord 2 Remove the cabinet front 3 If an out...

Страница 9: ...9 www thermastor com sales thermastor com Toll Free 1 800 533 7533 9 Vehere Electrical Wiring Figure 12 Vehere wiring diagram...

Страница 10: ...ntrol Low Pressure 9 4025278 1 Cord Wire Harness 10 4021470 1 Defrost Thermostat 4021648 1 Defrost Thermostat Mounting Clip 11 4021799 2 Filter Air 2 X 16 X 16 Grainger P N 6B958 12 4025087 1 Filter D...

Страница 11: ...care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any HI E Dry Ve...

Отзывы: