Service Parts List: HI-E DRY Vehere Dehumidifier 

ITEM  

PART NO. 

QTY.  

DESCRIPTION 

 

4021083 

Blower with Capacitor

4028249 

Capacitor, Run, 50MFD, 370v

4021589 

Capillary Tubes

4023604 

Caster, 2”, Plastic, Swivel

4028246 

Coil, Condenser

4028245 

Coil, Evaporator

4030131 

Compressor

 

4030121 

Compressor Overload

4029508 

Control, Low Pressure

4025278 

Cord & Wire Harness

10 

4021470 

Defrost Thermostat 

 

4021648 

Defrost Thermostat Mounting Clip

11 

4021799 

Filter, Air (2” X 16” X 16”), (Grainger P/N 6B958)

12 

4025087 

Filter/Drier

13 

4021626 

Hose Drain .56” x 8’

15 

4025283 

Humidity Controller, Cabinet Mounted

 

4021495 

Knob

16 

1096010 

Machine Screw, Stainless Steel, ¼-20 X 1” (for Front Cover)

17 

4022484 

Relay, SPDT, 24 Volt

18 

4023549 

Self-Retaining Nut, ¼-20

19 

4020988 

Service Valve Assembly w/ Core & Cap

20 

4025560 

Switch, SPDT, On-Off, for Fan

21 

4021818 

Accumulator

 

4025277 

Wiring Diagram (NS)

 

4022487 

24 Volt Transformer

Содержание HI-E Dry Vehere

Страница 1: ...dehumidifier resulting in a compact refrigeration system requiring less electric consumption This ensures the use of a standard 20 Amp electrical outlet and LOW OPERATING COSTS HI Capacity Vehere s pa...

Страница 2: ...60 RH 8 32 200 Air Temp Relative Humidity Pints Hour Pints Day 82 F 60 RH 8 33 200 80 F 60 RH 8 00 192 Air Temp Relative Humidity BTUs Hour KWH Day derived 82 F 60 RH 13 668 35 71 80 F 60 RH 13 299 34...

Страница 3: ...talled in a variety of locations to meet the owner s needs other considerations include 1 Providing access to a 115 VAC power outlet 7 power cord is provided 2 Locating near a floor or other suitable...

Страница 4: ...idification can be improved by adding an inlet and or outlet duct to circulate and destratify stagnant areas Add inlet or outlet ducting to create flow across the area s greatest length For areas with...

Страница 5: ...this manual Replace plastic housing 3 3 Electrical Requirements The Vehere can be plugged into any grounded 20 Amp circuit At 80 F 60 RH it draws 12 Amps A dedicated 20 Amp circuit is recommended 3 4...

Страница 6: ...it moving the controller toward Low to lower the humidity and toward High to increase the level of humidity in your pool or spa area Approximate Humidity Levels Per Setting Low 35 to 45 Relative Humid...

Страница 7: ...by giving up its heat to the air it discharges from the unit The refrigerant liquid then passes through two capillary tubes which cause the refrigerant pressure and temperature to drop It next enters...

Страница 8: ...4 Blower Replacement The blower has a PSC motor internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug the power cord 2 Remove the cabinet front 3 If an out...

Страница 9: ...9 www thermastor com sales thermastor com Toll Free 1 800 533 7533 9 Vehere Electrical Wiring Figure 12 Vehere wiring diagram...

Страница 10: ...ntrol Low Pressure 9 4025278 1 Cord Wire Harness 10 4021470 1 Defrost Thermostat 4021648 1 Defrost Thermostat Mounting Clip 11 4021799 2 Filter Air 2 X 16 X 16 Grainger P N 6B958 12 4025087 1 Filter D...

Страница 11: ...care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any HI E Dry Ve...

Отзывы: