BIOS Setup Utility
Advanced Setup Configurations
3-13
Themis Computer
If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while select-
ing Enhanced sets SATA#1 to native SATA mode. The options are Disabled, Com-
patible and
Enhanced
.
Configure SATA#1 as
This feature allows the user to select the drive type for SATA#1. The options are
IDE
, RAID and AHCI. (When the option-RAID is selected, the item “AHCI Code-
Base” and “ICH RAID Code Base” will appear. When AHCI is selected, the item
“AHCI CodeBase will be available.)
ICH RAID Code Base (This feature is available when the op-
tion-RAID is selected)
Select Intel to enable Intel's SATA RAID firmware to configure Intel's SATA RAID
settings. Select Adaptec to enable Adaptec's SATA RAID firmware to configure
Adaptec's SATA RAID settings. The options are
Intel
and Adaptec.
3.3.7.2 SATA#2 Configuration (This feature is available when the op-
tion-IDE is selected for SATA#1)
Selecting Enhanced will set SATA#2 to native SATA mode. The options are Dis-
abled, and
Enhanced
.
3.3.7.3 IDE Detect Timeout (sec)
Use this feature to set the time-out value for the BIOS to detect the ATA, ATAPI
devices installed in the system. The options are 0 (sec.), 5, 10, 15, 20, 25, 30, and
35
.
3.3.7.4 Primary IDE Master/Slave, Secondary IDE Master/Slave, Third
IDE Master, and Fourth IDE Master
These settings allow the user to set the parameters of the slots indicated above. Hit
<Enter> to activate the following submenu screen for detailed options of these items.
Set the correct configurations accordingly. The items included in the submenu are:
Type
Select the type of device connected to the system. The options are Not Installed,
Auto
, CD/DVD and ARMD.
LBA/Large Mode
Содержание RES-12XR3-S
Страница 5: ...iii Themis Computer VersionRevisionHistory Version 1 0 November 2010...
Страница 16: ...RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 xiv Themis Computer...
Страница 20: ...RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 xviii Themis Computer...
Страница 64: ...RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 2 20 Themis Computer...
Страница 99: ...BIOS Setup Utility BIOS Error Beep Codes 3 35 Themis Computer...
Страница 100: ...3 36 Themis Computer RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0...
Страница 108: ...Themis Computer RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 B 4...
Страница 132: ...E 4 Themis Computer RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0...