THELIGHT 4LIGHT Скачать руководство пользователя страница 5

 
 

1.

 

 

MAIN FEATURES 

 
4LIGHT is an LED panel housing a total of 96 high power LED. It has been specially designed and its 

colorimetry calibrated for professional photography, cinematography and television industry use. 
4LIGHT main innovative features are: 
 

 

Variable Colour Temperature 

 

Stable colour dimming 

 

Green/magenta bias control 

 

Very high light output 

 

Low power draw 

 

High CRI digitally calibrated light 

 

V-lock mount battery operated 

 

Lightweight lamp head 

 

 

NOTE ABOUT MEASURING COLOUR TEMPERATURE (CCT) 

 

4LIGHT incorporates the innovative THELIGHT technology based on high power LED tr Fresnel 
lens + CPU control software  to  obtain the wide  range of calibrated colour temperatures  combined 

with a high colour rendering index CCT. 

 
We must remark that colour meters in use today are designed for a full spectrum source such as 

incandescent  lights  and  therefore  cannot  be  used  to  accurately  read  the  correlated  colour 
temperature (CCT) of the light emitted by THELIGHT and other LED light fixtures. 
 
The eventual diversions to green display as CC10M or CC15M in hand-held colour meters are due to 
these unaccuracy on reading of the light emitted by LED and must not be considered. 
 
THELIGHT guarantees pure white light and correct colorimetry of the light delivered by its high power 
LED luminaries which have been calibrated in laboratory  according to CIE 13.3-1995  international 
standards for measurement of the CRI and chromatic coordinates (x, and CIE-1931). 
The  reliability  of  this  digital  equipment  is  supported  by  the  calibration  THELIGHT  has  made  in 
laboratory by spectrophotometer, which precision is half-yearly calibrated according to the National 
Institute of Standards (NIST) of the United States and of the Physikalisch-Technische Bundesanstalt 

(PTB) of Germany. 
In  order  that  the  advanced  THELIGHT  luminaries  could  be  used  together  with  other  light  sources, 
THELIGHT has accurately calibrated both the CCT and the chromatic coordinates to match them with  
traditional light sources following tungsten and daylight standards. 
 

The digital Control Unit allows a further and precise green/magenta correction along the whole scale 
of colour temperatures. 
 

 
 
 
 
 

 
 
 
 
 
 

 
 

 
 

Содержание 4LIGHT

Страница 1: ...Battery powered LED fixture User s Manual THELIGHT Luminary for cine and TV S L December 2011...

Страница 2: ...s not assume any responsibility for lighting failures caused by malfunction of this product The manufacturer disclaims liability for any damage to persons or property caused by inappropriate operation...

Страница 3: ...ny heat for what his use turns out to be very comfortable for the actors the lamp head acts as a heat sink through its back part Surface can reach a temperature between the 50 C and the 80 C Please us...

Страница 4: ...ontrol Unit and lamp head through the extension cable 11 Disconnecting the extension cable 12 Placing the VDC Control Unit in the stand mast 12 Securty cables 12 5 Digital Adjustments 13 Turning the p...

Страница 5: ...LED light fixtures The eventual diversions to green display as CC10M or CC15M in hand held colour meters are due to these unaccuracy on reading of the light emitted by LED and must not be considered T...

Страница 6: ...6 2 COMPONENTS AND ACCESSORIES Each 4LIGHT kit is composed by 1 x 4LIGHT lamp head 1 x VDC Control Unit VDC Control Unit DMX...

Страница 7: ...x Quick link swivel ball head with 3 8 pin 2 x Removable barn doors available separately 1 x 2 5 meters power cable 1 x 2 5 meters extension cable 1 x Hexagonal 5 8 16mm baby spud 1 x Quick link diffu...

Страница 8: ...nt view 1 Power switch 2 Colour temperature digital display 3 Intensity level digital display 4 Turbo status blue LED 5 Green magenta offset status green LED 6 Power output 7 Colour temperature adjust...

Страница 9: ...9 Rear view VDC Control Unit 1 Fuse receptacle 1 x 15A 2 XLR4 VDC input Rear view VDC Control Unit DMX 1 Fuse receptacle 1 x 15A 2 XLR DMX in 3 XLR4 VDC in 4 XLR DMX out...

Страница 10: ...four shoulder rivets drop into the receptacle The locking pin will snap into place when the plate is properly seated Warning Make sure the locking pin has totally entered in his housing before proceed...

Страница 11: ...tteries with a high continuous draw meaning a Discharge Current of at least 9A NOTE To power the 4LIGHT lamp head through mains power a power supply of at least 14A and 9 to 36V output must be used Da...

Страница 12: ...d mast You can place the VDC Control Unit in the stand mast for a handy use close to the lamp head To do so you will need to use a regular Super Clamp not included in the 4LIGHT kit and insert the Hex...

Страница 13: ...ge 9 NOTE If a power failure would happen or the cable would be accidentally disconnected the VDC Control Unit would entry on Error mode and the number 8 would show in the digital display To reset the...

Страница 14: ...bias control Green magenta bias switch located at the VDC Control Unit front panel lets you easily alter the colour of the light emittting at any colour temperature towards green or magenta in increm...

Страница 15: ...004 fixture3 address 007 DMX Channels When you connect your console to the VDC Control Unit DMX you will be able to control THELIGHT fixtures through 3 channels Channel 1 start address COLOUR TEMPERA...

Страница 16: ...ht beam angle is 35 The maximum light beam angle is given when the lamp head is bend at its more convex setting Barn doors installation Place the barn door axle into the external lamp head segment gro...

Страница 17: ...espective screws located on the lamp head Do the same thing with the low magnets and their power will automatically fix the diffuser to the lamp head NOTE The diffuser softens and broadens the light b...

Страница 18: ...ivel ball head with 10mm pin adjustable yoke ACCESSORIES quick link swivel ball head with 16mm female magnetic attach diffuser removable barn doors waterproof case VDC Control Unit DIMENSIONS 172 x 17...

Страница 19: ...ncandescent and daylight It is also remarkable the minimum green magenta deviation over the locus reference along the range of colour temperatures means minimal difference between THELIGHT chromaticit...

Страница 20: ...trometer model Spectro 320 serial number 30932004 with its accessory TOP 100 has been calibrated according to the United States National Institute of Standards NIST and the german Physikalisch Technis...

Страница 21: ...ry powered technology equipment ENVINRONMENTAL THELIGHT devices are certified and intended for indoor use lamp head IP21 VDC Control Unit IP41 LAMP HEAD OPERATI N TEMPERATURE from 20 to 30 C CONTROL U...

Страница 22: ...22...

Страница 23: ...MAGNETIC COMPATIBILITY THELIGHT is intended to Electromagnetic Environment E2 Commercial and light industrial STANDARD EN 61000 6 1 2005 Electromagnetic Compatibility Generic immunity standard Residen...

Страница 24: ...esulting from Failure to follow the instructions in the instruction manual Repair modification or overhaul not conducted by any authorized THELIGHT personnel Fire natural disaster act of God lightning...

Страница 25: ...25...

Страница 26: ...26 THELIGHT Luminary for cine and TV S L www thelight com es 2011 Copyright THELIGHT All rights reserved...

Отзывы: