THELIGHT 4LIGHT Скачать руководство пользователя страница 16

 
 

16 

7.

 

 

MECHANICAL ADJUSTMENTS

 

 

Beam angle variation 

Hold the lamp head from the outer segments and bend it in or out to the wanted concave or convex 
shape. Choose the light beam angle you need and the lamp head will remain at the chosen setting. 

When the lamp head is positioned at standard flat setting the light beam angle is 35º. 
The maximum light beam angle is given when the lamp head is bend at its more convex setting. 

 

  

   

 

 
Barn doors installation

 

Place  the  barn  door  axle  into  the  external  lamp 
head  segment  grooves.  Then  insert  one  end  of 

the  axle  into  the  hole  located  at  the  lamp  head 

exterior segment as shown in the picture. 
The right mounting position is achieved when the 
product name is visible facing outwards. 
 

 

Insert  the  other  barn  door  axle  end  into  the 

opposite  hole  located  at  the  lamp  head  exterior 
segment. 
 
 
 

 
 

 

               

 

 

 

Содержание 4LIGHT

Страница 1: ...Battery powered LED fixture User s Manual THELIGHT Luminary for cine and TV S L December 2011...

Страница 2: ...s not assume any responsibility for lighting failures caused by malfunction of this product The manufacturer disclaims liability for any damage to persons or property caused by inappropriate operation...

Страница 3: ...ny heat for what his use turns out to be very comfortable for the actors the lamp head acts as a heat sink through its back part Surface can reach a temperature between the 50 C and the 80 C Please us...

Страница 4: ...ontrol Unit and lamp head through the extension cable 11 Disconnecting the extension cable 12 Placing the VDC Control Unit in the stand mast 12 Securty cables 12 5 Digital Adjustments 13 Turning the p...

Страница 5: ...LED light fixtures The eventual diversions to green display as CC10M or CC15M in hand held colour meters are due to these unaccuracy on reading of the light emitted by LED and must not be considered T...

Страница 6: ...6 2 COMPONENTS AND ACCESSORIES Each 4LIGHT kit is composed by 1 x 4LIGHT lamp head 1 x VDC Control Unit VDC Control Unit DMX...

Страница 7: ...x Quick link swivel ball head with 3 8 pin 2 x Removable barn doors available separately 1 x 2 5 meters power cable 1 x 2 5 meters extension cable 1 x Hexagonal 5 8 16mm baby spud 1 x Quick link diffu...

Страница 8: ...nt view 1 Power switch 2 Colour temperature digital display 3 Intensity level digital display 4 Turbo status blue LED 5 Green magenta offset status green LED 6 Power output 7 Colour temperature adjust...

Страница 9: ...9 Rear view VDC Control Unit 1 Fuse receptacle 1 x 15A 2 XLR4 VDC input Rear view VDC Control Unit DMX 1 Fuse receptacle 1 x 15A 2 XLR DMX in 3 XLR4 VDC in 4 XLR DMX out...

Страница 10: ...four shoulder rivets drop into the receptacle The locking pin will snap into place when the plate is properly seated Warning Make sure the locking pin has totally entered in his housing before proceed...

Страница 11: ...tteries with a high continuous draw meaning a Discharge Current of at least 9A NOTE To power the 4LIGHT lamp head through mains power a power supply of at least 14A and 9 to 36V output must be used Da...

Страница 12: ...d mast You can place the VDC Control Unit in the stand mast for a handy use close to the lamp head To do so you will need to use a regular Super Clamp not included in the 4LIGHT kit and insert the Hex...

Страница 13: ...ge 9 NOTE If a power failure would happen or the cable would be accidentally disconnected the VDC Control Unit would entry on Error mode and the number 8 would show in the digital display To reset the...

Страница 14: ...bias control Green magenta bias switch located at the VDC Control Unit front panel lets you easily alter the colour of the light emittting at any colour temperature towards green or magenta in increm...

Страница 15: ...004 fixture3 address 007 DMX Channels When you connect your console to the VDC Control Unit DMX you will be able to control THELIGHT fixtures through 3 channels Channel 1 start address COLOUR TEMPERA...

Страница 16: ...ht beam angle is 35 The maximum light beam angle is given when the lamp head is bend at its more convex setting Barn doors installation Place the barn door axle into the external lamp head segment gro...

Страница 17: ...espective screws located on the lamp head Do the same thing with the low magnets and their power will automatically fix the diffuser to the lamp head NOTE The diffuser softens and broadens the light b...

Страница 18: ...ivel ball head with 10mm pin adjustable yoke ACCESSORIES quick link swivel ball head with 16mm female magnetic attach diffuser removable barn doors waterproof case VDC Control Unit DIMENSIONS 172 x 17...

Страница 19: ...ncandescent and daylight It is also remarkable the minimum green magenta deviation over the locus reference along the range of colour temperatures means minimal difference between THELIGHT chromaticit...

Страница 20: ...trometer model Spectro 320 serial number 30932004 with its accessory TOP 100 has been calibrated according to the United States National Institute of Standards NIST and the german Physikalisch Technis...

Страница 21: ...ry powered technology equipment ENVINRONMENTAL THELIGHT devices are certified and intended for indoor use lamp head IP21 VDC Control Unit IP41 LAMP HEAD OPERATI N TEMPERATURE from 20 to 30 C CONTROL U...

Страница 22: ...22...

Страница 23: ...MAGNETIC COMPATIBILITY THELIGHT is intended to Electromagnetic Environment E2 Commercial and light industrial STANDARD EN 61000 6 1 2005 Electromagnetic Compatibility Generic immunity standard Residen...

Страница 24: ...esulting from Failure to follow the instructions in the instruction manual Repair modification or overhaul not conducted by any authorized THELIGHT personnel Fire natural disaster act of God lightning...

Страница 25: ...25...

Страница 26: ...26 THELIGHT Luminary for cine and TV S L www thelight com es 2011 Copyright THELIGHT All rights reserved...

Отзывы: