THELIGHT 4LIGHT Скачать руководство пользователя страница 3

 
 

 

SAFETY PRECAUTIONS 

 
Various symbols are used throughout this instruction manual and on the product to prevent physical 
harm to you or other people and damage to property.  

The symbols and their meanings are explained below. 
 

   

    

 

Warning

 

Possible risk of injury or damage to equipment

 

 

 

Danger

 

This symbol indicates the risk of electric shock or fire danger that could 

result in injury or damage to equipment.

 

 

  

This  equipment  has  been  checked  and  meets  the  requirements  of  general  safety  for  electronic 

devices.  These  requirements  are  specified  to  provide  a  reasonable  protection  against 

electromagnetic interferences when the equipment is used in commercial environments. 
 

This  equipment  generates,  uses  and  can  emit  waves  of  radio  frequency,  and  if  not  properly  used 

following the instructions of this manual can produce interferences in radio communications. The use 

of this equipment in residential areas can produce interference, the user will be the only responsible 
of correcting them. 

 

CAUTION:

 Though the light generated by LED does not produce any heat, for what his use turns out 

to be very comfortable for the actors, the lamp head acts as a heat sink through its back part.  
Surface can reach a temperature between the 50 ºC and the 80 ºC. Please use protective gloves if 
you touch the lamp head at the heat sink. 
 

 

 

Danger

 

Do  not  attempt  to  open  any  of  the  device  or  component  housings.  To 
reduce  the  risk  of  electric  shock,  do  not  remove  lamp  head  or  Control 
Unit  cover.  No  user-serviceable  parts  inside.  Maintenance  and    repair 
work to be carried out only by THELIGHT Service Centre. 
 

Do  not  cover  the  aluminium  lamp  head  heat  sink  while  using  it.  Proper 
ventilation  must  be  provided.  Avoid  exposing  the  lamp  head  to  the  heat 
radiation of other light fixtures. 
 
The lamp head is equipped with high power LEDs. Due to their high light-
output intensity don’t stare directly into the light source. 

 

The V-lock mount or the XLR4 receptacle can be used for powering the 4LIGHT by battery. 
 

 

 

Warning

 

 
Relevant information on Battery use

 

Use only original chargers. Don’t short the battery. Respect the service 
and the safety manual of the battery.  
 
To  ensure  maximum  performance  of  the  4LIGHT  equipment  use  only 
high-load  capacity  batteries  with  a  high  continuous  draw  meaning  a 
Discharge Current of at least 9A. 
 

 
 

 

 
 

 

Содержание 4LIGHT

Страница 1: ...Battery powered LED fixture User s Manual THELIGHT Luminary for cine and TV S L December 2011...

Страница 2: ...s not assume any responsibility for lighting failures caused by malfunction of this product The manufacturer disclaims liability for any damage to persons or property caused by inappropriate operation...

Страница 3: ...ny heat for what his use turns out to be very comfortable for the actors the lamp head acts as a heat sink through its back part Surface can reach a temperature between the 50 C and the 80 C Please us...

Страница 4: ...ontrol Unit and lamp head through the extension cable 11 Disconnecting the extension cable 12 Placing the VDC Control Unit in the stand mast 12 Securty cables 12 5 Digital Adjustments 13 Turning the p...

Страница 5: ...LED light fixtures The eventual diversions to green display as CC10M or CC15M in hand held colour meters are due to these unaccuracy on reading of the light emitted by LED and must not be considered T...

Страница 6: ...6 2 COMPONENTS AND ACCESSORIES Each 4LIGHT kit is composed by 1 x 4LIGHT lamp head 1 x VDC Control Unit VDC Control Unit DMX...

Страница 7: ...x Quick link swivel ball head with 3 8 pin 2 x Removable barn doors available separately 1 x 2 5 meters power cable 1 x 2 5 meters extension cable 1 x Hexagonal 5 8 16mm baby spud 1 x Quick link diffu...

Страница 8: ...nt view 1 Power switch 2 Colour temperature digital display 3 Intensity level digital display 4 Turbo status blue LED 5 Green magenta offset status green LED 6 Power output 7 Colour temperature adjust...

Страница 9: ...9 Rear view VDC Control Unit 1 Fuse receptacle 1 x 15A 2 XLR4 VDC input Rear view VDC Control Unit DMX 1 Fuse receptacle 1 x 15A 2 XLR DMX in 3 XLR4 VDC in 4 XLR DMX out...

Страница 10: ...four shoulder rivets drop into the receptacle The locking pin will snap into place when the plate is properly seated Warning Make sure the locking pin has totally entered in his housing before proceed...

Страница 11: ...tteries with a high continuous draw meaning a Discharge Current of at least 9A NOTE To power the 4LIGHT lamp head through mains power a power supply of at least 14A and 9 to 36V output must be used Da...

Страница 12: ...d mast You can place the VDC Control Unit in the stand mast for a handy use close to the lamp head To do so you will need to use a regular Super Clamp not included in the 4LIGHT kit and insert the Hex...

Страница 13: ...ge 9 NOTE If a power failure would happen or the cable would be accidentally disconnected the VDC Control Unit would entry on Error mode and the number 8 would show in the digital display To reset the...

Страница 14: ...bias control Green magenta bias switch located at the VDC Control Unit front panel lets you easily alter the colour of the light emittting at any colour temperature towards green or magenta in increm...

Страница 15: ...004 fixture3 address 007 DMX Channels When you connect your console to the VDC Control Unit DMX you will be able to control THELIGHT fixtures through 3 channels Channel 1 start address COLOUR TEMPERA...

Страница 16: ...ht beam angle is 35 The maximum light beam angle is given when the lamp head is bend at its more convex setting Barn doors installation Place the barn door axle into the external lamp head segment gro...

Страница 17: ...espective screws located on the lamp head Do the same thing with the low magnets and their power will automatically fix the diffuser to the lamp head NOTE The diffuser softens and broadens the light b...

Страница 18: ...ivel ball head with 10mm pin adjustable yoke ACCESSORIES quick link swivel ball head with 16mm female magnetic attach diffuser removable barn doors waterproof case VDC Control Unit DIMENSIONS 172 x 17...

Страница 19: ...ncandescent and daylight It is also remarkable the minimum green magenta deviation over the locus reference along the range of colour temperatures means minimal difference between THELIGHT chromaticit...

Страница 20: ...trometer model Spectro 320 serial number 30932004 with its accessory TOP 100 has been calibrated according to the United States National Institute of Standards NIST and the german Physikalisch Technis...

Страница 21: ...ry powered technology equipment ENVINRONMENTAL THELIGHT devices are certified and intended for indoor use lamp head IP21 VDC Control Unit IP41 LAMP HEAD OPERATI N TEMPERATURE from 20 to 30 C CONTROL U...

Страница 22: ...22...

Страница 23: ...MAGNETIC COMPATIBILITY THELIGHT is intended to Electromagnetic Environment E2 Commercial and light industrial STANDARD EN 61000 6 1 2005 Electromagnetic Compatibility Generic immunity standard Residen...

Страница 24: ...esulting from Failure to follow the instructions in the instruction manual Repair modification or overhaul not conducted by any authorized THELIGHT personnel Fire natural disaster act of God lightning...

Страница 25: ...25...

Страница 26: ...26 THELIGHT Luminary for cine and TV S L www thelight com es 2011 Copyright THELIGHT All rights reserved...

Отзывы: