Connect a battery on the V-lock mount
Either the V-lock mount or the XLR4 receptacle can be used for powering the 4LIGHT by battery.
Any battery form 9 to 36 V can be used.
Relevant information on Battery use
Use only original chargers. Don’t short the battery. Respect the service and the safety manual of
the battery.
When powering the 4LIGHT through the XLR4 connector located at
the back of the VDC Control Unit check the proper polarity as shown
in the picture at the Control Unit bottom.
To ensure maximum performance of the 4LIGHT equipment use only
high-load capacity batteries with a high continuous draw meaning a
Discharge Current of at least 9A..
NOTE:
To power the 4LIGHT lamp head through mains power a power supply of at least 14A
and 9 to 36V output must be used.
Danger
To avoid electric shocks and/or damages in the equipment the
power switch located at the VDC Control Unit front panel must be off
before connecting or disconnecting cables.
3.
Connecting VDC Control Unit and lamp head through the extension cable
Connect the connector in the circular
receptacle at the VDC Control Unit front
panel.
Verify the correct alignment of the
connectors before inserting them.
Rotate the locking ring until it clicks into
the lock position.
Connect the same way the other end of
the extension cable in the input
receptacle coming out from the lamp
head.