• To switch the PIR from presence to absence mode, press the
   

lock/unlock

 button and you will see 2 flashes from the LED 

   receiver of the PIR, this indicates that the PIR is unlocked and
   ready to receive further instructions from the remote control.
   Next press the 

Semi Auto

 button on the 

IR10AB

 remote 

   control. The LED  receiver light will flash once for up to 2 
   seconds and dissapear, this indicates that the PIR is now in
   

Semi Auto

 (absence mode).

• When the PIR set to absence mode, the unit will not switch 
   on automatically when someone walks in the detection area. 
• The person in the room must press the retractable push 
   button for the light to switch on. From this point onwards as 
   long as detection in the area has constant movement, the 
   PIR will continue to keep the luminaire or attached load 
   swtiched on, until the subject has moved out of the detection 
   area and the time delay function takes over. 
• For example if set to 10 minutes the PIR will begin to 
   countdown from this value once nothing is in the detection 
   area. If a subject is detected the time delay will reset.

Switching From Presence To Absence Mode:

Switching From Absence To Presence Mode:

• To switch the PIR from absence to presence mode, press the
   

lock/unlock

 button and you will see 2 flashes from the LED 

   receiver of the PIR. Next press the 

Auto

 button on the 

   IR10AB

 remote control. The LED receiver light will flash 

   twice and dissapear, this indicates that the PIR is now in 
   

Auto

 (presence mode). There will be up to a 1 minute delay 

   in changing modes where the PIR will not switch.       

Содержание TIMEGUARD PDSM362AB

Страница 1: ...Presence Detector With 360 Surface Mount PIR Model PDSM362AB 1 Channel I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Optional Absence Detection...

Страница 2: ...eaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR and install in accordance with the current IEE wiring and Building Regulations Che...

Страница 3: ...Construction Polycarbonate Dimensions H x W x D 105mm x 105mm x 48mm PIR Ceiling Projection 48mm If a 2 channal surface PIR is required model number PDSMSB Surface Mount Box along with PDFM362AB 2 Ch...

Страница 4: ...ensure the best performance from the PIR and the appointed approach path Effective Approach Path ACROSS Ineffective Approach Path TOWARDS Avoid positioning the PIR near any sources of heat in and aro...

Страница 5: ...are removed or the circuit breaker turned off An isolating switch should be installed to enable the power to be switched ON and OFF to the PIR This allows the unit to be easily switched OFF for mainte...

Страница 6: ...points on the base plate for the installtion required Pass the 230V 50Hz mains supply and load cables through the hole and prepare for termination Drill the holes and insert he rawl plugs into positio...

Страница 7: ...ed to Neutral BlueorBlacktoN Locate the terminal connections and terminate the cables into the terminal block ensuring that the correct polarity is observed and that all bare conductors are sleeved Se...

Страница 8: ...ion area when the PIR is triggered and the load will turn ON for the minimum set amount of time Once you are happy with the pickup area of the PIR you can set the Lux dial in the anticlockwise directi...

Страница 9: ...ards as long as detection in the area has constant movement the PIR will continue to keep the luminaire or attached load swtiched on until the subject has moved out of the detection area and the time...

Страница 10: ...IR10AB is an optional remote control that is sold separately If absence detection is required the IR10AB will be needed to change modes over LUX control adjustment Auto mode only Time delay adjustmen...

Страница 11: ...de of the UK All shipping costs are to be paid in advance before a replacement is sent Problem Cause Solution False activation Luminaire switches on for no apparent reason Heat sources as described in...

Страница 12: ...com or call the helpdesk on 020 8450 0515 Qualified Customer Support Coordinators will be online to assist in resolving your query For a product brouchure please contact Timeguard Limited Victory Par...

Отзывы: