Страница 1: ...al User remote control theSenda S option 2 Safety Danger of death through electric shock or fire Installation should only be carried out by a qualified electrician WARNING Work on electrical systems may only be carried out by qualified electricians or by instructed persons under the guidance and supervision of a qualified electrician in accordance with the technical regulations applying to electri...

Страница 2: ... automatically fully automa tic device or after the button is operated semi automatic device Lighting time delay The minimum time delay 10 s 60 min is adjustable It adjusts automatically to the user s behaviour and can incre ase to 30 minutes or drop back to the set minimum time With settings 2 min or 30 min the time delay remains unchanged at the set value If someone goes into an unoccu pied room...

Страница 3: ...nnel As with 2 channel but with free choice between central light measurement A and integral light measurement average of light measurements A B C in the case of lighting channel C3 Switching Direct light influences the light measurement Avoid placing floor lamps or suspended lighting directly below the detector Constant light control The detector must be positioned in such a way that it only dete...

Страница 4: ...er parallel switching Several masters can be used in parallel switching Each master controls its lighting groups according to its own brightness measurements Time delays and brightness setpoint values are set individually on each master Presence continues to be detected by all detectors Master DALI DALI DA DA S1 S2 S3 P N L N L EVG Master DA DA S1 S2 S3 P N L EVG Master with 2 lighting groups and ...

Страница 5: ... mode Selection eco eco plus x x Presence switch on delay Value range in seconds minutes x Presence time delay Value range in seconds minutes x x Parameter Description Can be checked SendoPro theSenda B App Can be changed SendoPro theSenda B App Can be changed theSenda P Switch on dimming value C1 C2 C3 Value range in x Configuration type C1 C2 Selection auto man x x x Configuration type C3 Select...

Страница 6: ...rightness The currently prevailing brightness is measured below the presence detector If the prevailing brightness is below the setpoint value the light is switched on when a presence is detected in configuration type fully automatic device A separate brightness setpoint value is available for each lighting channel C1 C2 C3 Value range Lux values with SendoPro theSenda B App manage ment remote con...

Страница 7: ...ery sensitive By selecting the test presence operating mode the set sensi tivity increment is not changed Lighting time delay The time delay applies jointly to all lighting channels Value range Adjustable values with SendoPro 868 A manage ment remote control 10 s 60 min In the theSenda P installation remote control the following values are available 10 s button 30 s 60 s 2 min 10 min 20 min 60 min...

Страница 8: ...nda B App Switches lighting off after a set amount of time 5 min 9 h Lighting is never switched off never off Manual dimming response With constant lighting control the manual dimming res ponse can be selected with the manual dimming response parameter Value range with SendoPro theSenda B App Constant light control remains active temporarily after manual dimming to the current brightness value as ...

Страница 9: ...on and off together x Control command Description Can be triggered SendoPro theSenda B App Can be triggered theSenda P Teach in channel C1 Lighting channel C1 execution x x Teach in channel C2 Lighting channel C2 execution x x Teach in channel C3 Lighting channel C3 execution x Teach in channel C1 C2 C3 Activate for all lighting chan nels C1 C3 x Presence test On Off x x Light test On Off x Restar...

Страница 10: ...s them in a list This stage is indicated by an LED flashing pattern 5 x on briefly every 3 s and depending on the size of the system can last up to 3 min If no DALI ECG is connected to the detector or a DALI line is interrupted the detector shows this with the LED flashing pattern LED is on and flashes off briefly twice every 3 s If the system is OK the detector automatically enters con figuration...

Страница 11: ...mal operation and configuration is complete If so required the configuration can be completed by pressing End left hand function button In this case the system will not be ready for use If Change group assignment is selected the right arrow button can be used to switch to the next DALI ECG without changing the lighting group Otherwise the sequence remains the same When all desired changes have bee...

Страница 12: ... Channel Operating voltage Colour Type Item number Ceiling installation Light 230 V AC White theRonda P360 330 DALI WH 2080045 Troubleshooting Fault Cause Light does not switch on and or off if pre sence is detected and in darkness Brightness setpoint value is set too low detector set on semi automatic light was switched off manually via button or theSenda S person not within detection area obstru...

Страница 13: ...e en Cover clip for area restriction Item No 9070921 Details www theben de en theSenda P Item No 9070910 Details www theben de en theSenda S Item No 9070911 Details www theben de en theSenda B App Artikel Nr 9070985 Details www theben de en 13 Contact Theben AG Hohenbergstraße 32 72401 Haigerloch GERMANY Tel 49 7474 692 0 Fax 49 7474 692 150 Hotline Tel 49 7474 692 369 hotline theben de www theben...