10. Troubleshooting 

Fault

Cause

Light does not switch 

on or off if presence 

is detected and in 

darkness

Lux value is set too low; detector set to semi-

automatic; light was switched off manually via 

button or remote control; person not within detec-

tion area; obstruction(s) interrupting detection; 

time delay set too short

Light stays on with 

detection of presence 

despite sufficient 

brightness 

Lux value is set too high; light was briefly switched 

on manually via button or with the remote control 

(wait 30 min.); detector is in test mode

Light does not switch 

off, or light switches on 

spontaneously when 

no one is present 

Thermal sources of interference in the detection 

area: fan heaters, incandescent lamps/halogen 

spotlights, moving objects (e.g. curtains hanging in 

open windows); 

load (EBs, relays) not cleared

Button does not work

Device still in the start-up phase; illuminated 

button was used without neutral conductor; 

push button not fed to the master

Light cannot be 

switched off with the 

button

Button is not connected to the detector. Check the 

button wiring.

Device does not 

respond

Short circuit or several phases in parallel swit-

ching! Disconnect detector from the power supply 

for 5 min (thermal fuse)

Error flashing 

 

(4 x per second)

Error in self-test; 

device not functional!

11. Technical data

Operating voltage: 

230 V AC, + 10%/– 15% 

Frequency: 

50/60 Hz

Standby output:

0.4 W +/– 15% (without orientation light) 

Switching load:

L/L‘: 10 A with cos 

ϕ

 = 1; H1/H2: 2 A with  

cos 

ϕ

 = 1 (only 2060755), 

2 2060760 do not switch any load

Minimum load:

10 mA

Contact type A:

µ contact

Switching capacity A:

Incandescent/halogen 

lamp load:

Compact/fluorescent 

lamps:

LED lamps:

2 2 2060750, 2 2060755:  

2300 W

2 2 2060750, 2 2060755:  

1150 VA

2 2 2060750, 2 2060755: 

< 2 W: type. 40 W

> 2 W: type. 450 W

2 2060760:  –

2 2060770:  *

Switching capacity H:

50 W/50 VA (max. 2 A) (2 2060755)

Contact type H:

µ contact

Protection rating: 

IP 20 in accordance with EN 60529

Protection class: 

II in accordance with EN 60598-1

Operating temperature: 

–15 °C … +45 °C

Brightness setting range:  – 2 2 2060750:  5 – 1000 lx 

– 2 2060755:  5 – 3000 lx 

– 2 2060760:  –

– 2 2060770:  5 – 1000 lx

Presence time delay: 

10 s – 120 min (2 2060755)

Lighting time delay:

– 2 2 2060750:  10 s (pulse)  

    – 40 min  

– 2 2060755:  10 s (pulse) 

   – 60 min/pulse

– 2 2060760:  –

– 2 2060770:  pulse 
In the case of switching with 2060670 and 

2060770 the turn-on time corresponds to the 

time set on the staircase light timer switch.

Presence switch-on 

delay:

0 s – 10 min (2 2060755)  

Installation height

0.8 – 1.2 m

Detection angle: 

170°

Detection area:

– across

– frontal

14 x 17 m

12 x 10 m

Software:

Class A

Energy efficiency class: 

A+

* only for staircase light timer switch control

Cleaning and service

 

†

Only use a dry, soft cloth to clean the device surface.

 

†

Do not use any cleaning agents or solvents.

Disposal

 

†

Dispose of device in environmentally sound manner  

(electronic waste)

12. Dimensional drawings

theMura S180-100 UP (2060750)

37.00

68.00

theMura S180-100 UP WH (2060650) + theMura S180-101 UP WH (2060655) 

56.50

53.75

85.00

85.00

85.00

68.00

45.00

45.00

theMura S180-101 B UP (2060755)

85.00

85.00

68.00

50.00

theMura S180 Slave UP WH (2060660) + theMura S180-100 2W UP WH (2060670)

45.00

45.00

theMura S180 Slave B UP (2060760)

68.00

32.00

50.00

theMura S180-100 2W B UP (2060770)

theMura S180-100 UP N WH (2060653)

70.80

85.00

56.50

53.75

85.00

85.00

45.00

45.00

Содержание 2060650

Страница 1: ...es ponding theSenda Plug app iOS Android theSenda B app for short bezel frames adapted for different switch ranges can be ordered optionally theMura S180 100 bezel frames adapted for different switch ranges can be ordered optionally see www theben de theMura 2 Safety Assembly and installation should only be carried out by a qualified electrician somebody who has completed appropriate professional ...

Страница 2: ...A 1 3 6 6 plus 8 max 6 detectors with ELPA 041 047 LThe time delay is set at the staircase light timer switch Do not connect the lighting directly to the detector The 4 conductor switching must be used for the stair case light timer switch L N Master L L Master L L N L 4 3 e g ELPA 2 x theMura S180 100 2W UP onlyTheben devices max 12 pieces 5 Installation LFor installation in device housing concea...

Страница 3: ...he potentiometer to the desired time 10 s 1 min 5 min 10 min 30 min If you wish to use the pulse function e g for a staircase light timer switch Set the potentiometer to As long as motion is detected the contact closes every 10 s for 0 5 s LAt the 2 wire motion detector theMura S180 100 2W no time delay can be set The time delay set on the staircase lighting timer switch applies The time delay of ...

Страница 4: ... min theMura S180 101 When the button is pressed briefly the light switches on for a certain time depending on the duration of motion and the set time delay LWith theMura S180 101 the surrounding brightness is checked after 30 min If there is sufficient brightness the light is switched off despite the presence of persons Switching off manually 2 min 30 s 30 s 30 s 2 s 2 s t t t Normalbetrieb Norma...

Страница 5: ...te control Open the theSenda Plug app Press the Bluetooth symbol in the app on the top left hand side Briefly press the Bluetooth button on theSenda B LED flashes red devices are searched for Confirm with OK LED lights up red 9 Parameters and control commands via app 1 Parameters Brightness setpoint value A theSenda B app theSenda P Brightness actual value A Check of the current measured actual br...

Страница 6: ...vity The detector has 3 sensitivity levels Level Sensitivity 1 Very insensitive 2 Insensitive 3 Standard default theSenda B app theSenda P Time delay A theSenda B app theSenda P Short presence A If a room is only occupied briefly the channel A time delay is ended early 2 min provided that the set time delay is 2 min Channel function H Channel H presence isolated contact e g to control a fan in the...

Страница 7: ...n it can be switched on manually but not switched off The light will not be switched off again until after the set time delay Orientation light time delay The integrated orientation light conveys a sense of security and good orientation in dark rooms and corridors Time delay When the channel A time delay has expired the orientation light comes on for the set time delay On The orientation light alw...

Страница 8: ...enables use even in rooms with alcoves The function is activated as soon as the light channel A is switched on Each time an acoustic signal is detected the channel A time delay is restarted If the light goes out the microphone is only activated briefly LIf the set brightness target value A is exceeded the micro phone is switched off Level Sensitivity Off Deactivated default 1 Insensitive 2 Standar...

Страница 9: ... Acoustic sensor sensitivity Off LED display motion Off Switch on behaviour Start up phase 45 s after restoration of power The red LED flashes at one second intervals all switch contacts are closed The detector does not respond to push button com mands and remote control commands When no one is present all contacts open after 45 s Operation The detector is ready for operation LED off LED display L...

Страница 10: ...ad Compact fluorescent lamps LED lamps 2060650 2060653 2060750 2060655 2060755 2300 W 2060650 2060653 2060750 2060655 2060755 1150 VA 2060650 2060653 2060750 2060655 2060755 2 W type 40 W 2 W type 450 W 2060660 2060760 2060670 2060770 Switching capacity H 50 W 50 VA max 2 A 2060655 2060755 Contact type H µ contact Protection rating IP 20 in accordance with EN 60529 Protection class II in accordanc...

Страница 11: ...11 13 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Phone 49 7474 692 0 Fax 49 7474 692 150 Hotline Phone 49 7474 692 369 hotline theben de Addresses telephone numbers etc www theben de ...

Отзывы: