Test Interface Connections
To connect the test interface to the device under test you must select the proper patch
cable depending on which interface you are testing and the termination type if using
the optical ports. There is no specific order of connection required. You can connect
the patch cord to the test device or network device first.
Impedance Selection
2-wire signaling supports voice-band 600, 900 and 1200
Ω impedances. 4-Wire signal-
ing also supports the impedances plus 100 (T1) and 135
Ω (DDS). To change receive
and transmit impedances, tap on the impedance pull-down menu and select the de-
sired impedance. The RCV and XMT are always the same impedance.
Some features are enabled or disabled based on impedance and 2/4 Wire selection i.e.
600, 900, 1200 are voice-band impedances and will enable voice-band test features.
100 & 135 Ohm are wideband impedances and will enable wideband features.
Signaling Mode Selection
Upon selection of 2-wire Signaling defaults to LS-Loop-Start Station signaling mode.
To change signaling modes simply tap on Station (PBX). Tap the desired Emulation
(CO/PBX) and Signaling type (LS, GS, E&M I-V, DID and DID-wink, Selective Signal-