Test Interface Connections
Test Interface Connections
To connect the test interface to the device under test you must select the proper patch
cable depending on which interface you are testing and the termination type if using
the optical ports. There is no specific order of connection required. You can connect
the patch cord to the test device or network device first.
DDS 4-Wire Configuration
Select the desired data rate by tapping on the 56K Primary Mode (default and most
command data rate) and select 64k, 56K, or sub-rates 2.4K, 4.8K, 9.6K,1 9.2K, and
38.4K speed. Select timing clock source mode desired. If connecting to an OCU se-
lect NW clock. Connect the 4-wire local loop to the RJ48 port marked DDS.
Receive Loopbacks
The test set will respond to Latching or Alternating CSU, Alternating DSU and Latching
CCITT V.54 loopback.