![Textron Greenlee Communications DataScout 10G Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/textron/greenlee-communications-datascout-10g/greenlee-communications-datascout-10g_user-manual_1098069098.webp)
96
T1 (DS1) Timing Testing & TSG Threshold
To test Multi-Channel circuits such as those of a TSG output, connect the supplied
cable to the TSG bank, and press the 10-Channel Auto TSG or the Test Off button
then “
scan all channels
” at the bottom of the menu. By selecting Auto-TSG or Scan-
all-channels the DataScout 10G will start at channel 01 and will cycle through all 10
channels at the selected Interval and display the Frequency (64000Hz nominal), Vpp of
Tip (Voltage peak-to -peak), and Phase between Tip and Ring or Tip and ref (depend-
ing on the Tip to Ring or Tip to Ref selection).
Channel Selections are located under the Test OFF button. Channel 01 is used to test
the circuit connected to the Single bantam jack. If no circuit is connected to the Single
bantam jack the test set will select and analyze the first pair (Channel 01) of the cir-
cuit(s) connected via the Multi-Channel connector. To analyze channels manually se-
lect the Test OFF button and select the channel number (01-10) you wish to test. Note
that the results are displayed to the right of the respective channel number.
Test Interval
Press the
Set Interval
button to change the test analysis duration of each channel.
The intervals are 2, 4, 8(default), 15, 20, 30, and 45 seconds. Select the desired inter-
val and press
OK
. To fully test CC, it is recommended a minimum duration of least 4
seconds. 2 seconds can be used as a quick test to check that signals are present on
the channels.
CC Amplitude Measurements
Press the
VPP TIP
button to change to the following display:
►
+Vpk Tip
– Positive Peak Voltage on Tip
►
-Vpk Tip
– Negative Peak Voltage on Tip
►
Vpp Tip
– Voltage Peak to Peak on Tip
►
+Vpk Ring
– Positive Peak Voltage on Ring
►
-Vpk Ring
– Negative Peak Voltage on Ring
►
Vpp Ring
– Voltage Peak to Peak on Ring
T1 (DS1) Timing Testing & TSG Threshold
Upon power up select the DS1-DS3 icon. You MUST configure the T1-A port for Fram-
ing, Term/Monitor, TSG Level and Coding before starting T1 Timing test from the Tim-
ing screen.
For T1 to Reference testing the T1-B must also be configured to match that of the in-
coming T1 Reference. The DS1 Test system and the TIMING analysis system work in
concert to ensure T1 clock signals are error free.
Содержание Greenlee Communications DataScout 10G
Страница 1: ...2015 Greenlee Communications 52071568 Users Manual DataScout 10G 10Gx Version 11...
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 26: ......
Страница 40: ......
Страница 58: ......
Страница 66: ......
Страница 86: ......
Страница 102: ......
Страница 114: ......
Страница 115: ......