92
Select Sync or Async mode, clocking source and note the frequency displayed under
the clock tab, and finally select the cable type (RS232/V.35). Note the handshake line
are highlighted Yellow if active. In DCE mode the test set activates DSR,CTS, DCD.
The DTR & RTS lines are activated by the DTE.
Press the BERT pull-down to select the desired BERT pattern. Note patterns are listed
on previous page.
Byte Encoder Display
Above the BERT Tab is the Receive and Transmit bits labeled 1-8 bits, the Receive is
the test set input and is useful in seeing what type of data is being received. To the
right of RX/TX bit display is Async Errors only displayed and updated in Async mode.
Auto Mode
If this option was purchased press the Auto button (upper left of the screen) to Auto
detect the cable is plugged into the test set. The test set will configure for what cable is
detected.
Other Features
Up/Down buttons
These buttons increase or decrease the internal frequency by 100Hz steps.
Invert button
This button inverts the BERT pattern that is selected.
Bi-Directional loopback button
This button is useful for checking cable connections, press the Bi-Directional Loopback
to loop toward the test set and towards the DTE (DCE mode) or DCE (DTE mode).
Содержание Greenlee Communications DataScout 10G
Страница 1: ...2015 Greenlee Communications 52071568 Users Manual DataScout 10G 10Gx Version 11...
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 26: ......
Страница 40: ......
Страница 58: ......
Страница 66: ......
Страница 86: ......
Страница 102: ......
Страница 114: ......
Страница 115: ......