background image

Page 13

CL-B101D40RPM(d0097) manual

CL-B101D40RPM

Add to the basic model number the order code suffix for each standard option required. The last suffix is to 

indicate how many different special options and or accessories that you may require to be included with this product. 

Ordering Example: CL-B101D40RPM-VRR-PS1-IF05-OIC-R11-OA2 plus ZR and an OP-N4/144X36

Ordering Information

WARRANTY

Texmate warrants that its products are free from defects in material and workmanship under 

normal use and service for a period of one year from date of shipment. Texmate’s obligations 

under this warranty are limited to replacement or repair, at its option, at its factory, of any of 

the products which shall, within the applicable period after shipment, be returned to Texmate’s 

facility, transportation charges pre-paid, and which are, after examination, disclosed to the 

satisfaction of Texmate to be thus defective. The warranty shall not apply to any equipment 

which shall have been repaired or altered, except by Texmate, or which shall have been 

subjected to misuse, negligence, or accident. In no case shall Texmate’s liability exceed the 

original purchase price. The aforementioned provisions do not extend the original warranty 

period of any product which has been either repaired or replaced by Texmate.

USER’S RESPONSIBILITY

We are pleased to offer suggestions on the use of our various products either by way of 

printed matter or through direct contact with our sales/application engineering staff. However, 

since we have no control over the use of our products once they are shipped, NO WARRANTY 

WHETHER OF MERCHANTABILITY, FITNESS FOR PURPOSE, OR OTHERWISE is made 

beyond the repair, replacement, or refund of purchase price at the sole discretion of Texmate. 

Users shall determine the suitability of the product for the intended application before using, 

and the users assume all risk and liability whatsoever in connection therewith, regardless 

of any of our suggestions or statements as to application or construction. In no event shall 

Texmate’s liability, in law or otherwise, be in excess of the purchase price of the product.
Texmate cannot assume responsibility for any circuitry described. No circuit patent or soft-

ware licenses are implied. Texmate reserves the right to change circuitry, operating software, 

specifications, and prices without notice at any time.

BASIC MODEL NUMBER

CL-B101D40RPM          RPM, 101 Seg. Bargraph, 4 Digit. . . . . . . . . . . . . . . . .

Standard Options for this Model Number

 

Order Code Suffix 

Description 

List

DISPLAY

VRR. . . . .Red LED Bargraph w/4 Digit Red DPM, Vertical. . . . . . . . . . . . . . . . . . . . . . . N/C

VGG  . . . .Green LED Bargraph w/4 Digit Green DPM, Vertical . . . . . . . . . . . . . . . . . . . . . .

VGR  . . . .Green LED Bargraph w/4 Digit Red DPM, Vertical  . . . . . . . . . . . . . . . . . . . . . . . $15

VRG  . . . .Red LED Bargraph w/4 Digit Green DPM, Vertical  . . . . . . . . . . . . . . . . . . . . . . . $10

VTG. . . . .Tri-Color Bargraph w/4 Digit Green DPM, Vertical . . . . . . . . . . . . . . . . . . . . . . . . $55

VTR. . . . .Tri-Color Bargraph w/4 Digit Red DPM, Vertical  . . . . . . . . . . . . . . . . . . . . . . . . . $45
HRR  . . . .Red LED Bargraph w/4 Digit Red DPM, Horizontal. . . . . . . . . . . . . . . . . . . . . . . $5

HGG  . . . .Green LED Bargraph w/4 Digit Green DPM, Horizontal. . . . . . . . . . . . . . . . . . . . $30

HGR  . . . .Green LED Bargraph w/4 Digit Red DPM, Horizontal  . . . . . . . . . . . . . . . . . . . . . $20

HRG  . . . .Red LED Bargraph w/4 Digit Green DPM, Horizontal  . . . . . . . . . . . . . . . . . . . . . $15

HTG  . . . .Tri-Color Bargraph w/4 Digit Green DPM, Horizontal. . . . . . . . . . . . . . . . . . . . . . $60

HTR. . . . .Tri-Color Bargraph w/4 Digit Red DPM, Horizontal  . . . . . . . . . . . . . . . . . . . . . . . $50
DSGG . . .Dual Scale Green LED Vertical Bargraph w/4 Digit Green DPM. . . . . . . . . . . . . . $30

DSGR  . . .Dual Scale Green LED Vertical Bargraph w/4 Digit Red DPM  . . . . . . . . . . . . . . . $20

DSRG  . . .Dual Scale Red LED Vertical Bargraph w/4 Digit Green DPM  . . . . . . . . . . . . . . . $15

DSRR  . . .Dual Scale Red LED Vertical Bargraph w/4 Digit Red DPM. . . . . . . . . . . . . . . . . $5

DSTG  . . .Dual Scale Tri-Color Vertical Bargraph w/4 Digit Green DPM. . . . . . . . . . . . . . . . $60

DSTR  . . .Dual Scale Tri-Color Vertical Bargraph w/4 Digit Red DPM  . . . . . . . . . . . . . . . . . $50

POWER SUPPLY

PS1 . . . . .85-265VAC/95-300VDC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/C

 

PS2. . . . .15-48VAC/10-72VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $35

INPUT MODULES (Partial List. See www.texmate.com)

Unless otherwise specified Texmate will ship all modules precalibrated with factory pre-

selected ranges and/or scalings as shown in 

BOLD

 type.

IF05. . . . Universal Frequency / RPM 

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $40

ANALOG OUTPUT

OIC  . . . . .Isolated 16 Bit Current Output, 4-20mA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $35

OIV  . . . . .Isolated 16 Bit Voltage Output, 0-10VDC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $35

RELAY  OUTPUT

R1 . . . . . .Single 4A Form A Relay  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $37

R2 . . . . . .Dual 4A Form A Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $68

R11 . . . . .Single 9A Form C Relay  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $35

R12 . . . . .Dual 9A Form C Relays   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $70

R13 . . . . .Dual 9A Form C & One 4A Form A Relays  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $100

R14 . . . . .Dual 9A Form C & Dual 4A Form A Relays  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $130

R15 . . . . .Single 9A Form C & Dual 4A Form A Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . $95

R16 . . . . .Single 9A Form C & Single 4A Form A Relays. . . . . . . . . . . . . . . . . . . . . . . . . . .

$65

Special Options and Accessories 

 

Part Number 

Description 

List

SPECIAL OPTIONS (Specify Inputs or Outputs & Req. Reading)

ZR. . . . . . . . . . . . . . . Calibrated Range Change to another Standard Range  . . . . . . . . . . . $20

ZS . . . . . . . . . . . . . . . Custom display scaling within standard ranges  . . . . . . . . . . . . . . . . . $24

ZS-AO. . . . . . . . . . . . Custom scaling of analog output . . . . . . . . . . . . . . . . . . . . . . . . . . . . $60

 

ACCESSORIES (Specify Serial # for Custom Artwork Installation)

75-DMC14436B  . . . . . Side Slide Brackets-Wide opening (2 pc). . . . . . . . . . . . . . . . . . . . $10

75-DMC144X36  . . . . . Side Slide Brackets-stand. (2 pc) - extra set  . . . . . . . . . . . . . . . . . $10

93-PLUG2P-DP. . . . . . Extra Screw Terminal Conn., 2 Pin Power Plug  . . . . . . . . . . . . . . . $3

93-PLUG2P-DR  . . . . . Extra Screw Terminal Conn., 2 Pin Plug. . . . . . . . . . . . . . . . . . . . . $3

93-PLUG3P-DR  . . . . . Extra Screw Terminal Conn., 3 Pin Plug. . . . . . . . . . . . . . . . . . . . . $5

93-PLUG4P-DR  . . . . . Extra Screw Terminal Conn., 4 Pin Plug. . . . . . . . . . . . . . . . . . . . . $6

93-PLUG5P-DR  . . . . . Extra Screw Terminal Conn., 5 Pin Plug. . . . . . . . . . . . . . . . . . . . . $7

OP-MTL144x36. . . . . . Metal Surround Case, includes screw mounting clips  . . . . . . . . . . $35

OP-MTLCLIP. . . . . . . . Screw Mounting Clips (2 pc) - to screw tighten slide brackets   . . . . . . . .$10

OP-N4/144X36 . . . . . .  144x36mm clear lockable front cover-NEMA 4X, splash proof. . . . . . . . . .$35

OP-PA/144X36  . . . . . . Panel Adapter for 144x36mm from 6 inch cutout  . . . . . . . . . . . . . $15

For Custom Face Plates and Scales see page 14.

Prices subject to change without notice.

1934 Kellogg Ave., Carlsbad, CA 92008

Tel: 1-760-598-9899 • USA 1-800-839-6283 • 1-800-TEXMATE

Fax: 1-760-598-9828 • Email: [email protected] • Web: www.texmate.com 

CL-B101D40RPM Technical Manual Copyright © 2019 Texmate Inc. All rights 

reserved. Published by: Texmate Inc. USA. Information in this Technical Manual 

is subject to change without notice due to correction or enhancement. The 

information described in this manual is proprietary to Texmate, Inc. and may 

not be copied, reproduced or transmitted, in whole or in part, in connection with 

the design, manufacture, or sale of apparatus, device or private label product 

without the express written consent of Texmate, Inc.

BASIC MODEL #

DISPLAY

POWER SUPPLY

INPUT MODULES

ANALOG OUTPUT

RELAY OUTPUT

OPTIONS / ACCESSORIES

OA____

Содержание CL-B101D40RPM

Страница 1: ...Conventions 2 Input Specs Depends on Input signal conditioner A D Converter 14 bit single slope Accuracy 0 05 of reading 2 counts Temp Coeff 100 ppm C Typical Warm up time 2 minutes Conversion Rate 10 conversions per second Typical Digital Display 4 digit 0 56 LED red std green optn Range 0 to 9999 counts Bargraph Display 101 segment 235º circular bar red std green optn or tricolor optn Polarity A...

Страница 2: ...xplain software programming procedures logic diagrams are used to visually assist in following the programming steps The following symbols are used throughout the logic diagrams to represent the buttons and indicators on the meter Programming Conventions X XXX XX XX XXX X XXXX XXXX Front Panel Buttons Program Button The P button is used to move from one program step to the next When pressed at the...

Страница 3: ...INT VIEW MODE Bargraph Center Point Display Selection cto This branch will only appear if the analog output option is installed Back to Operational Display Digital Display ON OFF Selection diSP Sub menu MODE Calibration Mode Calibration Input Calibration Output Calibrate Analog Output Low cLo Calibrate Analog Output High chi Select the Digital Reading at which the Analog Output Hi chi will occur S...

Страница 4: ...lution PPR 1 Using the and buttons enter the number of pulese per revolution Any number between 1 and 9999 may be enterd 2 Press the P button Display toggles between rg and the previous range setting STEP D Select the Range 1 Using the and buttons selete the required range There are three ranges with resolutions of 0 1 max 999 9 RPM 1 max 9999 RPM and 10 RPM max 99 99 x 10000 RPM 2 Press the P but...

Страница 5: ...p for Input Signals up to 3999 counts Bargraph lights up for Input Signals above 4000 counts Bar High Bar Low Bar High Bar Low 0 25 75 100 50 0 25 75 100 50 No bargraph display Digital display No bargraph display Digital display An example of setting the digital span of the bargraph display to be different than the digital display range The bargraph can be set to display full scale 0 101 bars any ...

Страница 6: ... is off If the digital display is selected to be off pressing any button to make programming changes or to view setpoints activates the digital display When the procedure is complete the digital display will then automatically switch off The Display Bargraph settings are now complete Operational Display STEP E STEP F See Example of Bargraph Center Point Display Mode Selection Above From Digital Sp...

Страница 7: ...any value from 0 3 mA to 18 mA mA output selected or from 0 6 V to 8 V volt output selected However the output of cLo must always be less than the value selected for chi If a reversed analog output is desired the values selected to establish the Digital Span can be reversed see top of page 6 For digital readings outside the Digital Span selected the analog output will not go any lower than the cal...

Страница 8: ...to the desired hysteresis hYSt value 2 Press the P button Display toggles between SP2 and the previous SP2 setting STEP F Set Setpoint 2 SP2 1 Using the and buttons adjust the display to the desired SP2 value 2 Press the P button Display toggles between hySt and the previous hySt setting STEP G Set the Hysteresis hYSt Setting for Setpoint 2 1 Using the and buttons adjust the display to the desired...

Страница 9: ...Bargraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color setting STEP T Select Bargraph Color when the bar is ABOVE SP3 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP4 and the...

Страница 10: ...rminal plugs and do not insert remove or handle screw terminal plugs with live wires connected 17 16 14 15 8 9 10 11 See Leopard Family Input Signal Conditioning Modules 1 2 3 4 5 6 21 20 19 Relay Outputs Reserved for RS 485 LOCK COMMON No Function DIM ANALOG OUTPUT AC Neutral DC AC Line DC ANALOG OUTPUT 29 28 27 26 25 24 23 22 Standard plug in screw terminal connectors provided by Texmate Connect...

Страница 11: ...SP4 SP2 Relay Modules with 2 Non Isolated 4A Form A Relays and 2 Non Isolated 9A Form C Relays 29 28 27 25 26 24 23 22 DL Series Options Order Code OR51 OR52 OR53 OR54 210mA 210mA 210mA 210mA 210mA 210mA 210mA 210mA 210mA 210mA SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Relay Modules with 4 Independent 300V 210mA DC only 29 28 27 25 26 24 23 22 DL Series Options Order Code OR31 OR32 OR33 OR34 5A 5A 5A 5A 5A ...

Страница 12: ...s for input output leads is recommended with shield connection to earth ground near the meter preferred 4 A circuit breaker or disconnect switch is required to disconnect power to the meter The breaker switch should be in close proximity to the meter and marked as the disconnecting device for the meter or meter circuit The circuit breaker or wall switch must be rated for the applied voltage e g 12...

Страница 13: ...en LED Bargraph w 4 Digit Red DPM Horizontal 20 HRG Red LED Bargraph w 4 Digit Green DPM Horizontal 15 HTG Tri Color Bargraph w 4 Digit Green DPM Horizontal 60 HTR Tri Color Bargraph w 4 Digit Red DPM Horizontal 50 DSGG Dual Scale Green LED Vertical Bargraph w 4 Digit Green DPM 30 DSGR Dual Scale Green LED Vertical Bargraph w 4 Digit Red DPM 20 DSRG Dual Scale Red LED Vertical Bargraph w 4 Digit G...

Отзывы: